edoc

One-minute whole-brain magnetization transfer ratio imaging with intrinsic B1-correction

Afshari, Roya and Santini, Francesco and Heule, Rahel and Meyer, Craig H. and Pfeuffer, Josef and Bieri, Oliver. (2020) One-minute whole-brain magnetization transfer ratio imaging with intrinsic B1-correction. Magnetic Resonance in Medicine, 85 (5). pp. 2686-2695.

[img] PDF - Accepted Version
1351Kb
[img] PDF - Published Version
Restricted to Repository staff only

1349Kb

Official URL: https://edoc.unibas.ch/94380/

Downloads: Statistics Overview

Abstract

Purpose : Magnetization transfer ratio (MTR) histograms are widely used for the assessment of diffuse pathological changes in the brain. For broad clinical application, MTR scans should not only be fast but confounding factors should be minimized for high reproducibility. To this end, a one-minute whole brain spiral MTR method with intrinsic B 1 -field correction is introduced. Methods : A spiral multi-slice spoiled gradient echo sequence with adaptable magnetization transfer (MT) saturation pulses (angle b) is proposed. After a low-resolution single-shot spiral readout and a dummy preparation period, high-resolution images are acquired using an interleaved spiral readout. For whole brain MTR imaging, fifty interleaved slices with three different MT contrasts (b = 0°, 350°, 550°) together with an intrinsic B 1 -field map are recorded in 58.5s on a clinical 3T system. From the three contrasts, two sets of MTR images are derived and used for subsequent B 1 correction, assuming a linear dependency on b. For validation, a binary spin bath model is used. Results : For the proposed B 1 -correction scheme, numerical simulations indicate for brain tissue a decrease of about a factor of ten for the B 1 -related bias on MTR. As a result, upon B 1 -correction, MTR differences in gray and white matter become markedly accentuated and the reproducibility of MTR histograms from scan-rescan experiments is improved. Furthermore, B 1 -corrected MTR histograms show a lower variability for age-matched normal appearing brain tissue. Conclusion : From its speed and offering intrinsic B 1 -correction, the proposed method shows excellent prospects for clinical studies that explore MT-effects based on MTR histogram analysis.
Faculties and Departments:03 Faculty of Medicine > Bereich Querschnittsfächer (Klinik) > Radiologie USB > Radiologische Physik (Bieri)
03 Faculty of Medicine > Departement Klinische Forschung > Bereich Querschnittsfächer (Klinik) > Radiologie USB > Radiologische Physik (Bieri)
UniBasel Contributors:Afshari, Roya and Bieri, Oliver and Santini, Francesco
Item Type:Article, refereed
Article Subtype:Research Article
Publisher:Wiley
ISSN:0740-3194
e-ISSN:1522-2594
Note:Publication type according to Uni Basel Research Database: Journal article
Language:English
Language:English
Identification Number:
edoc DOI:
Last Modified:21 Apr 2023 11:58
Deposited On:21 Apr 2023 11:58

Repository Staff Only: item control page