edoc

Infection intensity-dependent accuracy of reagent strip for the diagnosis of Schistosoma haematobium and estimation of treatment prevalence thresholds

Grolimund, C. M. and Bärenbold, O. and Hatz, C. F. and Vennervald, B. J. and Mayombana, C. and Mshinda, H. and Utzinger, J. and Vounatsou, P.. (2022) Infection intensity-dependent accuracy of reagent strip for the diagnosis of Schistosoma haematobium and estimation of treatment prevalence thresholds. PLoS Negl Trop Dis, 16 (4). e0010332.

[img] PDF - Published Version
Available under License CC BY (Attribution).

1372Kb

Official URL: https://edoc.unibas.ch/90518/

Downloads: Statistics Overview

Abstract

BACKGROUND: Reagent strip to detect microhematuria as a proxy for Schistosoma haematobium infections has been considered an alternative to urine filtration for individual diagnosis and community-based estimates of treatment needs for preventive chemotherapy. However, the diagnostic accuracy of reagent strip needs further investigation, particularly at low infection intensity levels. METHODS: We used existing data from a study conducted in Tanzania that employed urine filtration and reagent strip testing for S. haematobium in two villages, including a baseline and six follow-up surveys after praziquantel treatment representing a wide range of infection prevalence. We developed a Bayesian model linking individual S. haematobium egg count data based on urine filtration to reagent strip binary test results available on multiple days and estimated the relation between infection intensity and sensitivity of reagent strip. Furthermore, we simulated data from 3,000 hypothetical populations with varying mean infection intensity to infer on the relation between prevalence observed by urine filtration and the interpretation of reagent strip readings. PRINCIPAL FINDINGS: Reagent strip showed excellent sensitivity even for single measurement reaching 100% at around 15 eggs of S. haematobium per 10 ml of urine when traces on reagent strip were considered positive. The corresponding specificity was 97%. When traces were considered negative, the diagnostic accuracy of the reagent strip was equivalent to urine filtration data obtained on a single day. A 10% and 50% urine filtration prevalence based on a single day sampling corresponds to 11.2% and 48.6% prevalence by reagent strip, respectively, when traces were considered negative, and 17.6% and 57.7%, respectively, when traces were considered positive. CONCLUSIONS/SIGNIFICANCE: Trace results should be included in reagent strip readings when high sensitivity is required, but excluded when high specificity is needed. The observed prevalence of reagent strip results, when traces are considered negative, is a good proxy for prevalence estimates of S. haematobium infection by urine filtration on a single day.
Faculties and Departments:09 Associated Institutions > Swiss Tropical and Public Health Institute (Swiss TPH)
09 Associated Institutions > Swiss Tropical and Public Health Institute (Swiss TPH) > Department of Epidemiology and Public Health (EPH) > Biostatistics > Bayesian Modelling and Analysis (Vounatsou)
09 Associated Institutions > Swiss Tropical and Public Health Institute (Swiss TPH) > Former Units within Swiss TPH > Health Impact Assessment (Utzinger)
09 Associated Institutions > Swiss Tropical and Public Health Institute (Swiss TPH) > Department of Directorate (DIR) > Medical Services (Künzli/Neumayr)
UniBasel Contributors:Grolimund, Carla and Bärenbold, Oliver and Hatz, Christoph and Utzinger, Jürg and Vounatsou, Penelope
Item Type:Article, refereed
Article Subtype:Research Article
ISSN:1935-2735 (Electronic)1935-2727 (Linking)
Note:Publication type according to Uni Basel Research Database: Journal article
Language:English
Related URLs:
Identification Number:
edoc DOI:
Last Modified:22 Dec 2022 16:33
Deposited On:22 Dec 2022 16:33

Repository Staff Only: item control page