edoc

Comparing Physical Container Closure Integrity Test Methods and Artificial Leak Methodologies

Peláez, Sarah S. and Mahler, Hanns-Christian and Herdlitschka, Christoph and Wertli, Toni and Kahl, Matthias and Koulov, Atanas and Matter, Anja and Singh, Satish K. and Widmer, Martina and Germershaus, Oliver and Mathaes, Roman. (2019) Comparing Physical Container Closure Integrity Test Methods and Artificial Leak Methodologies. PDA Journal of Pharmaceutical Science and Technology, 73 (3). pp. 220-234.

Full text not available from this repository.

Official URL: https://edoc.unibas.ch/85145/

Downloads: Statistics Overview

Abstract

The sterility of drug products intended for parenteral administration is a critical quality attribute (CQA) because it serves to ensure patient safety and is thus a key requirement by health authorities. While sterility testing is a probabilistic test, the assurance of sterility is a holistic concept including adequate design of manufacturing facilities, process performance, and product design. Container closure integrity testing (CCIT) is necessary to confirm the integrity of a container closure system (CCS), until the end of a product's shelf life. The new and revised United States Pharmacopeia (USP) General Chapter is a comprehensive guidance on CCI. Nevertheless, practical considerations including the choice of CCIT methods, the acceptance criteria, or the positive control samples (artificial leaks) must be addressed by the pharmaceutical manufacturer.This study is the first to provide a systematic comparison of four commonly used physical CCIT (pCCIT) methods [Helium (He) leak, vacuum decay, laser-based headspace analysis (HSA), and dye ingress] and four commonly used modes of creating artificial leaks (laser-drilled micro holes, copper wire introduced leaks, and two types of capillary leaks).The results from these experiments provide comprehensive data to allow a direct comparison of the capabilities of the individual methods. The results confirmed that the He leak detection method, which is considered the "gold-standard" for pCCIT regarding method sensitivity, indeed demonstrates the highest detection sensitivity (lowest detection limit). In comparison to the dye ingress method, HSA and vacuum decay also demonstrated better detection sensitivity in our study.Capillary leaks with orifice diameter (capillary leak with flow according to an ideal orifice) and micro holes yielded similar leak rates, whereas capillaries with nominal diameters yielded significantly lower leak rates. In conclusion, method sensitivity cannot be compared by means of a leak diameter, but requires the consideration of multiple impacting factors (e.g., path length, uniformity).; LAY ABSTRACT:; Sterility of drug products intended for parenteral administration is a critical quality attribute to ensure patient's safety and is thus a key requirement by health authorities. The absence of microbial contamination must be demonstrated by container closure integrity (CCI) of the container closure system (CCS). Currently, the revised United States Pharmacopeia (USP) General Chapter provides the most extensive guidance on how CCI should be assessed. Nevertheless, practical considerations on the choice of an appropriate CCIT method, artificial leaks or the choice of an acceptance criteria are lacking and must be addressed by the pharmaceutical manufacturer.This study provides a systematic comparison of four commonly used physical CCIT (pCCIT) methods [Helium (He) leak, vacuum decay, laser-based headspace analysis (HSA) and dye ingress] and four commonly used modes of creating artificial leaks (laser-drilled micro holes, copper wire introduced leaks, and two types of capillary leaks).
Faculties and Departments:05 Faculty of Science > Departement Pharmazeutische Wissenschaften > Pharmazie > Pharmaceutical Technology (Huwyler)
UniBasel Contributors:Pelaez, Sarah
Item Type:Article, refereed
Article Subtype:Research Article
Publisher:Parenteral Drug Association (PDA)
ISSN:1079-7440
e-ISSN:1948-2124
Note:Publication type according to Uni Basel Research Database: Journal article
Identification Number:
Last Modified:02 Mar 2022 10:10
Deposited On:02 Mar 2022 10:10

Repository Staff Only: item control page