edoc

First magnetic resonance imaging-guided aortic stenting and cava filter placement using a polyetheretherketone-based magnetic resonance imaging-compatible guidewire in swine: proof of concept

Kos, Sebastian and Huegli, Rolf and Hofmann, Eugen and Quick, Harald H. and Kuehl, Hilmar and Aker, Stephanie and Kaiser, Gernot M. and Borm, Paul J. A. and Jacob, Augustinus L. and Bilecen, Deniz. (2009) First magnetic resonance imaging-guided aortic stenting and cava filter placement using a polyetheretherketone-based magnetic resonance imaging-compatible guidewire in swine: proof of concept. Cardiovascular & interventional radiology : a journal of imaging in diagnosis and treatment, Vol. 32. pp. 514-521.

Full text not available from this repository.

Official URL: http://edoc.unibas.ch/dok/A6003234

Downloads: Statistics Overview

Abstract

The purpose of this study was to demonstrate feasibility of percutaneous transluminal aortic stenting and cava filter placement under magnetic resonance imaging (MRI) guidance exclusively using a polyetheretherketone (PEEK)-based MRI-compatible guidewire. Percutaneous transluminal aortic stenting and cava filter placement were performed in 3 domestic swine. Procedures were performed under MRI-guidance in an open-bore 1.5-T scanner. The applied 0.035-inch guidewire has a PEEK core reinforced by fibres, floppy tip, hydrophilic coating, and paramagnetic markings for passive visualization. Through an 11F sheath, the guidewire was advanced into the abdominal (swine 1) or thoracic aorta (swine 2), and the stents were deployed. The guidewire was advanced into the inferior vena cava (swine 3), and the cava filter was deployed. Postmortem autopsy was performed. Procedural success, guidewire visibility, pushability, and stent support were qualitatively assessed by consensus. Procedure times were documented. Guidewire guidance into the abdominal and thoracic aortas and the inferior vena cava was successful. Stent deployments were successful in the abdominal (swine 1) and thoracic (swine 2) segments of the descending aorta. Cava filter positioning and deployment was successful. Autopsy documented good stent and filter positioning. Guidewire visibility through applied markers was rated acceptable for aortic stenting and good for venous filter placement. Steerability, pushability, and device support were good. The PEEK-based guidewire allows either percutaneous MRI-guided aortic stenting in the thoracic and abdominal segments of the descending aorta and filter placement in the inferior vena cava with acceptable to good device visibility and offers good steerability, pushability, and device support.
Faculties and Departments:03 Faculty of Medicine > Bereich Querschnittsfächer (Klinik) > Radiologie USB
03 Faculty of Medicine > Departement Klinische Forschung > Bereich Querschnittsfächer (Klinik) > Radiologie USB
03 Faculty of Medicine > Bereich Querschnittsfächer (Klinik) > Ehemalige Einheiten Querschnittsfächer (Klinik) > Medizinische Radiologie (Steinbrich)
03 Faculty of Medicine > Departement Klinische Forschung > Bereich Querschnittsfächer (Klinik) > Ehemalige Einheiten Querschnittsfächer (Klinik) > Medizinische Radiologie (Steinbrich)
03 Faculty of Medicine > Bereich Querschnittsfächer (Klinik) > Ehemalige Einheiten Querschnittsfächer (Klinik) > Interventionelle Radiologie (Jacob)
03 Faculty of Medicine > Departement Klinische Forschung > Bereich Querschnittsfächer (Klinik) > Ehemalige Einheiten Querschnittsfächer (Klinik) > Interventionelle Radiologie (Jacob)
UniBasel Contributors:Jacob, Augustinus Ludwig and Bilecen, Deniz and Hügli, Rolf and Kos, Sebastian
Item Type:Article, refereed
Article Subtype:Research Article
Publisher:Springer
ISSN:0174-1551
Note:Publication type according to Uni Basel Research Database: Journal article
Related URLs:
Identification Number:
Last Modified:01 Mar 2013 11:14
Deposited On:01 Mar 2013 11:10

Repository Staff Only: item control page