edoc

Comparability of a hand-held nitric oxide analyser with online and offline chemiluminescence-based nitric oxide measurement

Schiller, Barbara and Hammer, Juerg and Barben, Juerg and Trachsel, Daniel. (2009) Comparability of a hand-held nitric oxide analyser with online and offline chemiluminescence-based nitric oxide measurement. Pediatric allergy and immunology, Vol. 20, H. 7. pp. 679-685.

Full text not available from this repository.

Official URL: http://edoc.unibas.ch/dok/A5250255

Downloads: Statistics Overview

Abstract

Schiller B, Hammer J, Barben J, Trachsel D. Comparability of a hand-held nitric oxide analyser with online and offline chemiluminescence-based nitric oxide measurement. Pediatr Allergy Immunol 2009. (c) 2009 The Authors Journal compilation (c) 2009 Blackwell MunksgaardPracticability is crucial for successful implementation of fractional exhaled nitric oxide (FeNO) measurement into asthma management. The study aimed at comparing a conventional chemiluminescence NO analyser (EcoMedics((R))) with a hand-held device (NIOX MINO((R))) and offline FeNO measurement using a commercially available system in an unselected cohort of children aged 6-16 yr. A secondary objective was to confirm FeNO stability over time in 15 samples from adult volunteers obtained using the offline system. Sixty-six children (mean +/- s.d. age 11.8 +/- 3.0 yr) underwent single breath FeNO measurement in triplets with each device. Offline collected FeNO was measured after offline breath collection into a Mylar balloon and subsequent analysis using the chemiluminescence NO analyser. Variability and between-method agreement were assessed, and stability over time within the Mylar balloons was tested by repeated hourly measurements. FeNO levels ranged from 2 to 113 p.p.b. Intra-class correlation was excellent (r = 0.98, p > 0.001 for each pair). Bland-Altman plots and back-transformation of logarithmic mean differences revealed fair agreement between methods. Stability over time was confirmed over 10 h both at room temperature and when stored under cooling conditions. FeNO values obtained using the chemiluminescence NO analyser, the portable NIOX MINO((R)) system and the offline collection technique show between-method agreement within clinically acceptable range.
Faculties and Departments:03 Faculty of Medicine > Bereich Kinder- und Jugendheilkunde (Klinik) > Kinder- und Jugendheilkunde (UKBB)
03 Faculty of Medicine > Departement Klinische Forschung > Bereich Kinder- und Jugendheilkunde (Klinik) > Kinder- und Jugendheilkunde (UKBB)
03 Faculty of Medicine > Bereich Kinder- und Jugendheilkunde (Klinik) > Kinder- und Jugendheilkunde (UKBB) > Pädiatrie (Frey)
03 Faculty of Medicine > Departement Klinische Forschung > Bereich Kinder- und Jugendheilkunde (Klinik) > Kinder- und Jugendheilkunde (UKBB) > Pädiatrie (Frey)
UniBasel Contributors:Trachsel, Daniel and Hammer, Jürg and Trachsel, Daniel
Item Type:Article, refereed
Article Subtype:Research Article
Publisher:Blackwell
ISSN:0905-6157
Note:Publication type according to Uni Basel Research Database: Journal article
Related URLs:
Identification Number:
Last Modified:10 Oct 2014 09:19
Deposited On:22 Mar 2012 13:39

Repository Staff Only: item control page