edoc

Exposure to radiofrequency electromagnetic fields: comparison of exposimeters with a novel body-worn distributed meter

Huss, A. and Dongus, S. and Aminzadeh, R. and Thielens, A. and van den Bossche, M. and Van Torre, P. and de Seze, R. and Cardis, E. and Eeftens, M. and Joseph, W. and Vermeulen, R. and Röösli, M.. (2021) Exposure to radiofrequency electromagnetic fields: comparison of exposimeters with a novel body-worn distributed meter. Environment international, 156. p. 106711.

[img] PDF - Published Version
Available under License CC BY-NC-ND (Attribution-NonCommercial-NoDerivatives).

939Kb

Official URL: https://edoc.unibas.ch/89104/

Downloads: Statistics Overview

Abstract

Background: Exposure to radiofrequency electromagnetic fields (RF-EMF) is often measured with personal exposimeters, but the accuracy of measurements can be hampered as carrying the devices on-body may result in body shielding. Further, the compact design may compromise the frequency selectivity of the sensor. The aim of this study was to compare measurements obtained using a multi-band body-worn distributed-exposimeter (BWDM) with two commercially available personal exposimeters (ExpoM-RF and EmeSpy 200) under real-life conditions. Methods: The BWDM measured power density in 10 frequency bands (800, 900, 1800, 2100, 2600 MHz, DECT 1900 MHz, WiFi 2.4 GHz; with separate uplink/downlink bands for 900, 1800 and 2100 MHz); using 20 separate antennas integrated in a vest and placed on diametrically opposite locations on the body, to minimize bodyshielding. RF-EMF exposure data were collected from several microenvironments (e.g. shopping areas, train stations, outdoor rural/ urban residential environments, etc.) by walking around pre-defined areas/routes in Belgium, Spain, France, the Netherlands and Switzerland. Measurements were taken every 1-4 s with the BWDM in parallel with an ExpoM-RF and an EmeSpy 200 exposimeter. We calculated medians and interquartile ranges (IQRs) and compared difference, ratios and correlations of geometric mean RF-EMF exposure levels per microenvironment as measured with the exposimeters and the BWDM. Results: Across 267 microenvironments, medians and IQR of total BWDM measured RF-EMF exposure was 0.13 (0.05-0.33) mW/m2. Difference: IQR of exposimeters minus BWDM exposure levels was
Faculties and Departments:09 Associated Institutions > Swiss Tropical and Public Health Institute (Swiss TPH)
09 Associated Institutions > Swiss Tropical and Public Health Institute (Swiss TPH) > Department of Epidemiology and Public Health (EPH) > Environmental Exposures and Health Systems Research > Physical Hazards and Health (Röösli)
UniBasel Contributors:Dongus, Stefan and Eeftens, Marloes and Röösli, Martin
Item Type:Article, refereed
Article Subtype:Research Article
ISSN:0160-4120
Note:Publication type according to Uni Basel Research Database: Journal article
Language:English
Related URLs:
Identification Number:
edoc DOI:
Last Modified:20 Dec 2022 10:36
Deposited On:20 Dec 2022 10:36

Repository Staff Only: item control page