Etter, Manina M. and Möhlenbruch, Markus and Weyland, Charlotte S. and Pérez-García, Carlos and Moreu, Manuel and Capasso, Francesco and Limbucci, Nicola and Nikoubashman, Omid and Wiesmann, Martin and Blackham, Kristine and Tsogkas, Ioannis and Sporns, Peter and Ospel, Johanna Maria and Brehm, Alex and Psychogios, Marios-Nikos. (2021) Initial Experience With the Trevo NXT Stent Retriever. Frontiers in Neurology, 12. p. 704329.
PDF
- Published Version
Available under License CC BY (Attribution). 177Kb |
Official URL: https://edoc.unibas.ch/84306/
Downloads: Statistics Overview
Abstract
Background:; The application of a new coating to the delivery wire of the Trevo retriever has the potential to improve its handling. We therefore report our initial experience with this new stent retriever for mechanical thrombectomy of large and medium vessel occlusions.; Methods:; We pooled data of four high-volume European stroke centers over the time period from October 2020 to February 2021. Patients were included in our study if the Trevo NXT stent retriever was used as a first-line device. Primary endpoints were first-pass near-complete or complete reperfusion, defined as mTICI score of ≥2c. Secondary endpoints were final reperfusion, National Institutes of Health Stroke Scale (NIHSS) at 24 h and discharge, device malfunctions, complications during the procedure, and subjective ratings of the interventionalists regarding device functionality.; Results:; Eighty patients (39 women, mean age 74 ± 14 years) were eligible for our study. Median NIHSS at admission was 15 (IQR, 8-19), and median Alberta Stroke Program Early CT Score at baseline was 9 (IQR, 8-10). In 74 (93%) patients a primary combined approach was used as first-line technique. First-pass near-complete reperfusion was achieved in 43 (54%) and first-pass complete reperfusion in 34 (43%) patients. Final near-complete reperfusion was achieved in 66 (83%) patients after a median of 1.5 (1-3) passes, while final successful reperfusion was observed in 96% of our cases. We observed no device malfunctions. Median NIHSS at discharge was 2 (IQR, 0-5), and 3 patients (4%) suffered a symptomatic intracranial hemorrhage.; Conclusions:; Based on our initial data, we conclude that the Trevo NXT is an effective and safe tool for mechanical thrombectomy especially when used for combined approaches.
Faculties and Departments: | 03 Faculty of Medicine > Bereich Querschnittsfächer (Klinik) > Radiologie USB > Neuroradiologie (Psychogios) 03 Faculty of Medicine > Departement Klinische Forschung > Bereich Querschnittsfächer (Klinik) > Radiologie USB > Neuroradiologie (Psychogios) |
---|---|
UniBasel Contributors: | Brehm, Alex and Psychogios, Marios-Nikos |
Item Type: | Article, refereed |
Article Subtype: | Research Article |
Publisher: | Frontiers Research Foundation |
e-ISSN: | 1664-2295 |
Note: | Publication type according to Uni Basel Research Database: Journal article |
Language: | English |
Identification Number: |
|
edoc DOI: | |
Last Modified: | 20 Aug 2021 07:40 |
Deposited On: | 20 Aug 2021 07:40 |
Repository Staff Only: item control page