edoc

Validation of automatic wear-time detection algorithms in a free-living setting of wrist-worn and hip-worn ActiGraph GT3X

Knaier, Raphael and Höchsmann, Christoph and Infanger, Denis and Hinrichs, Timo and Schmidt-Trucksäss, Arno. (2019) Validation of automatic wear-time detection algorithms in a free-living setting of wrist-worn and hip-worn ActiGraph GT3X. BMC public health, 19 (1). p. 244.

Full text not available from this repository.

Official URL: https://edoc.unibas.ch/69778/

Downloads: Statistics Overview

Abstract

Wrist-worn accelerometers are increasingly used in epidemiological studies to record physical activity. The accelerometer data are usually only analyzed if the convention for compliant wear time is met (i.e. ≥ 10 h per day) but the algorithms to detect wear time have been developed based on data from hip-worn devices only and have not been tested in a free-living setting. The aim of this study was to validate the automatic wear time detection algorithms of one of the most frequently used devices in a free-living setting.; Sixty-eight adults wore one ActiGraph GT3X+ accelerometer on the wrist and one on the hip and additionally recorded wear times for each device separately in a diary. Monitoring phase was during three consecutive days in a free-living setting. Wear time was computed by the algorithms of Troiano and Choi and compared to the diary recordings.; Mean wear time was over 1420 min per day for both devices on all days. Lin's concordance correlation coefficient for the wrist-worn wear time was 0.73 (0.60; 0.82) when comparing the diary with Troiano and 0.78 (0.67; 0.86) when comparing the diary with Choi. For hip-worn devices the respective values were 0.23 (0.13; 0.33) for Troiano and 0.92 (0.88; 0.95) for Choi. Mean and standard deviation values for absolute percentage errors for wrist-worn devices were - 1.3 ± 8.1% in Troiano and 0.9 ± 7.7% in Choi. The respective values for hip-worn devices were - 17.5 ± 10% in Troiano and - 0.8 ± 4.6% in Choi.; Hip worn devices may be preferred due to their higher accuracy in physical activity measurement. Automatic wear-time detection can show high errors in individuals, but on a group level, type I, type II, and total errors are generally low when the Choi algorithm is used. In a real-life setting and participants with a high compliance, the algorithm by Choi is sufficient to distinguish wear time from non-wear time on a group level.
Faculties and Departments:03 Faculty of Medicine > Departement Sport, Bewegung und Gesundheit > Bereich Sport- und Bewegungsmedizin > Sportmedizin (Schmidt-Trucksäss)
UniBasel Contributors:Hinrichs, Timo and Knaier, Raphael and Infanger, Denis and Höchsmann, Christoph and Schmidt-Trucksäss, Arno
Item Type:Article, refereed
Article Subtype:Research Article
ISSN:1471-2458
Note:Publication type according to Uni Basel Research Database: Journal article
Related URLs:
Identification Number:
Last Modified:08 Jul 2020 14:41
Deposited On:01 Jul 2020 14:06

Repository Staff Only: item control page