Meckel, Stephan and Glücker, Thomas M. and Kretzschmar, Martin and Scheffler, Klaus and Radue, Ernst-Wilhelm and Wetzel, Stephan G.. (2008) Display of dural sinuses with time-resolved, contrast-enhanced three-dimensional MR venography. Cerebrovascular Diseases, 25 (3). pp. 217-224.
Full text not available from this repository.
Official URL: https://edoc.unibas.ch/63179/
Downloads: Statistics Overview
Abstract
BACKGROUND: Time-resolved (TR) contrast-enhanced 3D MR angiography has recently received considerable attention for the workup of cerebrovascular diseases, foremost dural arteriovenous fistula and arteriovenous malformation, and potentially for the evaluation of dural sinus thrombosis. Thereby, the dynamic visualization of cerebral vessels is enabled similar to the principle of digital subtraction angiography. Yet, its voxel size is relatively large due to an inherent trade-off between the desired spatial and temporal resolutions. The goal of this study was to evaluate whether the limited spatial resolution of TR MR venography (MRV) is sufficient to visualize dural venous sinuses. METHODS: The prospective study included 20 patients without compromise of cerebral venous outflow. Two neuroradiologists independently graded the quality of visualization of 11 predefined dural venous sinuses on images of fast TR contrast-enhanced MRV (1.5 s/dataset; voxel size, 2 x 2 x 2.2 mm; acquisition time, 37.5 s) in comparison to time-of-flight (TOF) MRV (voxel size, 0.8 x 0.8 x 4 mm; acquisition time, 3 min 51 s) and steady-state contrast-enhanced 3D (VIBE) MRV (voxel size, 1.1 x 0.9 x 1.5 mm; acquisition time, 2 min 46 s). RESULTS: The torcular Herophili (p > 0.001), left (p > 0.001) and right (p > 0.01) transverse sinus, and right jugular bulb (p > 0.05) were visualized better at TR MRV than at TOF MRV. For visualization of the small inferior sagittal sinus, TR MRV was inferior to VIBE (p > 0.001) and TOF (p > 0.05) sequences. The visibility of all other dural sinuses was equal. CONCLUSION: Despite the inferior spatial resolution, TR MRV depicted some large dural sinuses more clearly than TOF MRV. To overcome the visualization of smaller venous structures, TR MRV can be applied complementarily with high-resolution steady-state contrast-enhanced MRV.
Faculties and Departments: | 03 Faculty of Medicine > Bereich Querschnittsfächer (Klinik) > Ehemalige Einheiten Querschnittsfächer (Klinik) > Medizinische Radiologie (Steinbrich) 03 Faculty of Medicine > Departement Klinische Forschung > Bereich Querschnittsfächer (Klinik) > Ehemalige Einheiten Querschnittsfächer (Klinik) > Medizinische Radiologie (Steinbrich) 03 Faculty of Medicine > Bereich Querschnittsfächer (Klinik) > Ehemalige Einheiten Querschnittsfächer (Klinik) > Neuroradiologie (Stippich) 03 Faculty of Medicine > Departement Klinische Forschung > Bereich Querschnittsfächer (Klinik) > Ehemalige Einheiten Querschnittsfächer (Klinik) > Neuroradiologie (Stippich) 03 Faculty of Medicine > Bereich Querschnittsfächer (Klinik) > Ehemalige Einheiten Querschnittsfächer (Klinik) > Radiologische Physik (Scheffler) 03 Faculty of Medicine > Departement Klinische Forschung > Bereich Querschnittsfächer (Klinik) > Ehemalige Einheiten Querschnittsfächer (Klinik) > Radiologische Physik (Scheffler) |
---|---|
UniBasel Contributors: | Scheffler, Klaus and Wetzel, Stephan G. and Glücker, Thomas M. and Radü, Ernst-Wilhelm |
Item Type: | Article, refereed |
Article Subtype: | Research Article |
Publisher: | Karger |
ISSN: | 1015-9770 |
e-ISSN: | 1421-9786 |
Note: | Publication type according to Uni Basel Research Database: Journal article |
Identification Number: |
|
Last Modified: | 10 Aug 2020 13:45 |
Deposited On: | 10 Aug 2020 13:45 |
Repository Staff Only: item control page