Comparing Luminex NxTAG-Respiratory Pathogen Panel and RespiFinder-22 for multiplex detection of respiratory pathogens

Beckmann, C. and Hirsch, H. H.. (2016) Comparing Luminex NxTAG-Respiratory Pathogen Panel and RespiFinder-22 for multiplex detection of respiratory pathogens. J Med Virol, 88 (8). pp. 1319-1324.

Full text not available from this repository.

Official URL: https://edoc.unibas.ch/61890/

Downloads: Statistics Overview

Abstract

Respiratory tract infection (RTI) involves a variety of viruses and bacteria, which can be conveniently detected by multiplex nucleic acid amplification testing (NAT). To compare the novel Luminex-based NxTAG-Respiratory Pathogen Panel (NxTAG-RPP) with the routine multiplex-ligation-NAT based RespiFinder-22(R) (RF-22), 282 respiratory specimens including nasopharyngeal swabs (71%), broncho-alveolar lavage (27%), throat swabs, tracheal secretions, and sputum (2%) from 116 children and 155 adults were extracted using a Corbett CAS1200 (Qiagen), and analyzed in parallel by the routine RF-22 and NxTAG-RPP. Concordant results were obtained in 263 (93.3%) cases consisting of concordant positives in 167 (59.2%) and concordant negatives in 96 (34%). Results were discordant in 19 (6.7%) consisting of 15 positive:negative, and 4 negative:positive results by NxTAG-RPP versus RF-22, respectively. Co-infections were observed in 10.3% with NxTAG-RPP and in 5.9% with RF-22. Most additional viral pathogens identified by the NxTAG-RPP involved dual infections with rhinovirus and RSV. Discordant samples were mainly due to low genome signals of Ct less than 36, when retested by QNAT suggesting a higher sensitivity of the NxTAG-RPP, also when detecting multiple infections. Hands-on time after extraction for 24 and 96 samples was 0.25 and >0.5 hr for the NxTAG-RPP, and 2 and 4 hr for the RF-22, respectively. The median turn-around time was 6 hr (range 5-7 hr) for NxTAG-RPP and 12 hr (range 8-16 hr) for RF-22. The NxTAG-RPP showed comparable detection rates for most respiratory pathogens, while hands-on and turn-around time were considerably shorter. The clinical significance of detecting multiple viruses needs further clinical evaluation. J. Med. Virol. 88:1319-1324, 2016. (c) 2016 Wiley Periodicals, Inc.
Faculties and Departments:03 Faculty of Medicine > Departement Biomedizin > Division of Medical Microbiology > Transplantation Virology (Hirsch)
UniBasel Contributors:Hirsch, Hans H.
Item Type:Article, refereed
Article Subtype:Research Article
ISSN:1096-9071 (Electronic) 0146-6615 (Linking)
Note:Publication type according to Uni Basel Research Database: Journal article
Related URLs:
Identification Number:
Last Modified:31 May 2020 17:48
Deposited On:31 May 2020 17:48

Repository Staff Only: item control page