Abstract

Gait analysis is commonly used to identify gait changes and fall risk in clinical populations and seniors. Body-worn inertial sensor based gait analyses provide a feasible alternative to optometric and pressure based measurements of spatiotemporal gait characteristics. We assessed validity and relative and absolute reliability of a body-worn inertial sensor system (RehaGait(®)) for measuring spatiotemporal gait characteristics compared to a standard stationary treadmill (Zebris(®)). Spatiotemporal gait parameters (walking speed, stride length, cadence and stride time) were collected for 24 healthy seniors (age: 75.3±6.7 years) tested on 2 days (1 week apart) simultaneously using the sensor based system and instrumented treadmill. Each participant completed walking tests (200 strides) at different walking speeds and slopes. The difference between the RehaGait(®) system and the treadmill was trivial (Cohen's d<0.2) except for speed and stride length at slow speed (Cohen's d, 0.35 and 0.49, respectively). Intraclass correlation coefficients (ICC) were excellent for temporal gait characteristics (cadence and stride time; ICC: 0.99-1.00) and moderate for stride length (ICC: 0.73-0.89). Both devices had excellent day-to-day reliability for all gait parameters (ICC: 0.82-0.99) except for stride length at slow speed (ICC: 0.74). The RehaGait(®) is a valid and reliable tool for assessing spatiotemporal gait parameters for treadmill walking at different speeds and slopes.
Faculties and Departments:03 Faculty of Medicine > Departement Biomedical Engineering > Biomechanics and Biomaterials
03 Faculty of Medicine > Bereich Operative Fächer (Klinik) > Bewegungsapparat und Integument > Traumatologie / Orthopädie (Jakob)
03 Faculty of Medicine > Departement Klinische Forschung > Bereich Operative Fächer (Klinik) > Bewegungsapparat und Integument > Traumatologie / Orthopädie (Jakob)
03 Faculty of Medicine > Departement Sport, Bewegung und Gesundheit > Bereich Bewegungs- und Trainingswissenschaft > Trainingswissenschaften (Zahner)
UniBasel Contributors:Donath, Lars and Lichtenstein, Eric and Pagenstert, Geert and Nüesch, Corina and Mündermann, Annegret
Item Type:Article, refereed
Article Subtype:Research Article
ISSN:1879-2219
Note:Publication type according to Uni Basel Research Database: Journal article
Identification Number:
Last Modified:24 Jul 2020 03:10
Deposited On:05 Mar 2019 18:37

Repository Staff Only: item control page