edoc

Ion-pair liquid-liquid-liquid microextraction of nerve agent degradation products followed by capillary electrophoresis with contactless conductivity detection

Xu, Li and Gong, Xiao Yang and Lee, Hian Kee and Hauser, Peter C.. (2008) Ion-pair liquid-liquid-liquid microextraction of nerve agent degradation products followed by capillary electrophoresis with contactless conductivity detection. Journal of Chromatography A, 1205 (1-2). pp. 158-162.

Full text not available from this repository.

Official URL: http://edoc.unibas.ch/dok/A6211744

Downloads: Statistics Overview

Abstract

The four nerve agent degradation products methylphosphonic acid (MPA), ethyl methylphosphonic acid (EMPA), isopropyl methylphosphonic acid (IMPA) and cyclohexyl methylphosphonic acid (CMPA) have been successfully extracted from aqueous sample solution by ion-pair liquid-liquid-liquid microextraction. In this Procedure, the target analytes in the sample solution were converted into their ion-pair complexes with tri-n-butyl amine and then extracted by an organic solvent (1-octanol) layer on top of the sample solution. Simultaneously, the analytes were back-extracted into a drop of an aqueous acceptor solution which was suspended in the organic phase at a microsyringe needle tip. The factors influential to extraction: type of organic solvent, type of ion-pair reagent and its concentration, pH values of sample solution and acceptor aqueous phase, stirring rate and extraction time were investigated in detail. After extraction, the drop of the acceptor solution was withdrawn into the syringe and injected into a capillary electrophoresis system for analysis. Using contactless conductivity detection, direct quantification of these compounds is possible. Moreover, large-volume sample injection was employed for further pre-concentration. Improvements in the limits of detection between 2.5 and 4 orders of magnitude could be achieved and concentrations at the ng/mL level can be determined. This newly established approach was successfully applied to a spiked river water sample.
Faculties and Departments:05 Faculty of Science > Departement Chemie > Chemie > Analytische Chemie (Hauser)
UniBasel Contributors:Hauser, Peter C. P. C.
Item Type:Article, refereed
Article Subtype:Research Article
Publisher:Elsevier
ISSN:0021-9673
Note:Publication type according to Uni Basel Research Database: Journal article
Identification Number:
Last Modified:29 Mar 2017 13:54
Deposited On:31 Jan 2014 09:49

Repository Staff Only: item control page