edoc

Accuracy of urine circulating cathodic antigen test for the diagnosis of Schistosoma mansoni in preschool-aged children before and after treatment

Coulibaly, Jean T. and N'gbesso, Yves K. and Knopp, Stefanie and N'guessan, Nicaise A. and Silué, Kigbafori D. and van Dam, Govert J. and N'goran, Eliézer K. and Utzinger, Jürg. (2013) Accuracy of urine circulating cathodic antigen test for the diagnosis of Schistosoma mansoni in preschool-aged children before and after treatment. PLoS neglected tropical diseases, Vol. 7, H. 3 , e2109.

Full text not available from this repository.

Official URL: http://edoc.unibas.ch/dok/A6124535

Downloads: Statistics Overview

Abstract

The Kato-Katz technique is widely used for the diagnosis of Schistosoma mansoni, but shows low sensitivity in light-intensity infections. We assessed the accuracy of a commercially available point-of-care circulating cathodic antigen (POC-CCA) cassette test for the diagnosis of S. mansoni in preschool-aged children before and after praziquantel administration.; A 3-week longitudinal survey with a treatment intervention was conducted in Azaguié, south Côte d'Ivoire. Overall, 242 preschoolers (age range: 2 months to 5.5 years) submitted two stool and two urine samples before praziquantel administration, and 86 individuals were followed-up posttreatment. Stool samples were examined with duplicate Kato-Katz thick smears for S. mansoni. Urine samples were subjected to POC-CCA cassette test for S. mansoni, and a filtration method for S. haematobium diagnosis.; Before treatment, the prevalence of S. mansoni, as determined by quadruplicate Kato-Katz, single CCA considering 'trace' as negative (t-), and single CCA with 'trace' as positive (t+), was 23.1%, 34.3% and 64.5%, respectively. Using the combined results (i.e., four Kato-Katz and duplicate CCA(t-)) as diagnostic 'gold' standard, the sensitivity of a single Kato-Katz, a single CCA(t-) or CCA(t+) was 28.3%, 69.7% and 89.1%, respectively. Three weeks posttreatment, the sensitivity of a single Kato-Katz, single CCA(t-) and CCA(t+) was 4.0%, 80.0% and 84.0%, respectively. The intensity of the POC-CCA test band reaction was correlated with S. mansoni egg burden (odds ratio = 1.2, p = 0.04). CONCLUSIONSSIGNIFICANCE: A single POC-CCA cassette test appears to be more sensitive than multiple Kato-Katz thick smears for the diagnosis of S. mansoni in preschool-aged children before and after praziquantel administration. The POC-CCA cassette test can be recommended for the rapid identification of S. mansoni infections before treatment. Additional studies are warranted to determine the usefulness of POC-CCA for assessing drug efficacy and monitoring the impact of control interventions.
Faculties and Departments:09 Associated Institutions > Swiss Tropical and Public Health Institute (Swiss TPH) > Former Units within Swiss TPH > Health Impact Assessment (Utzinger)
UniBasel Contributors:Utzinger, Jürg
Item Type:Article, refereed
Article Subtype:Research Article
Publisher:Public Library of Science
ISSN:1935-2727
Note:Publication type according to Uni Basel Research Database: Journal article
Related URLs:
Identification Number:
Last Modified:13 Sep 2013 07:59
Deposited On:13 Sep 2013 07:49

Repository Staff Only: item control page