edoc

Non-invasive central venous pressure measurement by compression ultrasound--a step into real life

Thalhammer, Christoph and Siegemund, Martin and Aschwanden, Markus and Gassmann, Mirjam and Baumann, Ulrich A. and Jaeger, Kurt A. and Imfeld, Stephan. (2009) Non-invasive central venous pressure measurement by compression ultrasound--a step into real life. Resuscitation, Vol. 80. pp. 1130-1136.

Full text not available from this repository.

Official URL: http://edoc.unibas.ch/dok/A6005076

Downloads: Statistics Overview

Abstract

AIM OF THE STUDY: Information on central venous pressure (CVP) is helpful in clinical situations like cardiac failure and sepsis. Compression ultrasound (CU) of a forearm vein has been shown to be a reliable method for CVP measurement when assessed by experienced personal under study conditions. To test the hypothesis, that CU can be reliably used for CVP measurement after a training program and using a portable ultrasound system, we investigated feasibility and accuracy of CU, comparing the results of vascular experts vs. trainees as well as high-end vs. a portable ultrasound system. METHODS: CU with non-invasive CVP measurement (CVP(ni)) was performed by four investigators in 50 patients of an intensive care unit and compared with invasive CVP measurement (CVP(i)). RESULTS: Feasibility was between 88 and 92% in the different investigator groups. CVP(ni) measurement showed a significant linear correlation (r=0.58-0.68; p>0.001) with CVP(i) in all groups. Mean difference between CVP(i) and CVP(ni) was 2.4+/-3.1mmHg and similar between the investigators. No differences were observed between measurements done by vascular experts and trainees, as well as between high-end and portable ultrasound systems. Further we demonstrated, that CU is able to detect changes in CVP during the respiratory cycle. CONCLUSIONS: After a training program CU can be used by non-vascular clinician for reliable CVP measurement with good quality portable systems. Furthermore, respiratory changes in CVP are detectable by CU. These data suggest CU to be an efficient method for measuring CVP under real life conditions.
Faculties and Departments:03 Faculty of Medicine > Bereich Querschnittsfächer (Klinik) > Anästhesiologie
03 Faculty of Medicine > Departement Klinische Forschung > Bereich Querschnittsfächer (Klinik) > Anästhesiologie
03 Faculty of Medicine > Bereich Medizinische Fächer (Klinik) > Angiologie
03 Faculty of Medicine > Departement Klinische Forschung > Bereich Medizinische Fächer (Klinik) > Angiologie
03 Faculty of Medicine > Bereich Medizinische Fächer (Klinik) > Ehemalige Einheiten Medizinische Fächer (Klinik) > Angiologie (Jäger)
03 Faculty of Medicine > Departement Klinische Forschung > Bereich Medizinische Fächer (Klinik) > Ehemalige Einheiten Medizinische Fächer (Klinik) > Angiologie (Jäger)
UniBasel Contributors:Jäger, Kurt A. and Thalhammer, Christoph and Siegemund, Martin
Item Type:Article, refereed
Article Subtype:Research Article
Publisher:Elsevier Science Ireland
ISSN:0300-9572
Note:Publication type according to Uni Basel Research Database: Journal article
Related URLs:
Identification Number:
Last Modified:01 Mar 2013 11:14
Deposited On:01 Mar 2013 11:10

Repository Staff Only: item control page