Repository logo
Log In
  1. Home
  2. Unibas
  3. Publications
  4. Performance and impact of GeneXpert MTB/RIF® and Loopamp MTBC Detection Kit® assays on tuberculosis case detection in Madagascar
 
  • Details

Performance and impact of GeneXpert MTB/RIF® and Loopamp MTBC Detection Kit® assays on tuberculosis case detection in Madagascar

Date Issued
2019-01-01
Author(s)
Rakotosamimanana, Niaina
Lapierre, Simon Grandjean
Raharimanga, Vaomalala
Raherison, Mamy Serge
Knoblauch, Astrid M.  
Raherinandrasana, Antso Hasina
Rakotoson, Andrianantenaina
Rakotonirina, Julio
Rasolofo, Voahangy
DOI
10.1186/s12879-019-4198-6
Abstract
Tuberculosis rapid molecular assays, including GeneXpert MTB/RIF® and Loopamp MTBC Detection Kit®, are highly sensitive and specific. Such performance does not automatically translate in improved disease control and highly depends on their use, local epidemiology and the diagnostic algorithms they're implemented within. We evaluate the performance of both assays and assess their impact on additional cases notification when implemented within WHO recommended tuberculosis diagnostic algorithms in Madagascar.; Five hundred forty eight presumptive pulmonary tuberculosis patients were prospectively recruited between November 2013 and December 2014 in Antananarivo, Madagascar, a high TB incidence sub-Saharan African urban setting. Both molecular assays were evaluated as first line or add-on testing following negative smear microscopy. Based on locally defined assay performance characteristics we measure the impact of both assays and WHO-recommended diagnostic algorithms on additional tuberculosis case notifications.; High sensitivity and specificity was confirmed for both GeneXpert MTB/RIF® (86.6% (95% CI 81.1-90.7%) and 97.4% (95% CI 94.9-98.8%)) and Loopamp MTBC Detection Kit® (84.6% (95% CI 78.9-89.0%) and 98.4% (95% CI 96.2-99.4%)). Implementation of GeneXpert MTB/RIF® and Loopamp MTBC Detection Kit® increased tuberculosis diagnostic algorithms sensitivity from 73.6% (95% CI 67.1-79.3%) up to 88.1% (95% CI 82.8-91.9%). This increase was highest when molecular assays were used as add-on testing following negative smear microscopy. As add-on testing, GeneXpert MTB/RIF® and Loopamp MTBC Detection Kit® respectively improved case detection by 23.8 and 21.2% (p < 0.05).; Including GeneXpert MTB/RIF® or Loopamp MTBC Detection Kit® molecular assays for TB detection on sputum samples from presumptive TB cases can significantly increase case notification in TB diagnostic centers. The TB case detection rate is further increased when those tests are use as second-line follow-on testing following negative smear microscopy results. A country wide scale-up and digital integration of molecular-based TB diagnosis assays shows promises for TB control in Madagascar.
File(s)
Loading...
Thumbnail Image
Name

20190709082752_5d2433e81589b.pdf

Size

980.2 KB

Format

Adobe PDF

Checksum

(MD5):10a61b42bae56c8ee833a6cf459ffbc6

University of Basel

edoc
Open Access Repository University of Basel

  • About edoc
  • About Open Access at the University of Basel
  • edoc Policy

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Privacy policy
  • End User Agreement