Variability and reproducibility of carotid structural and functional parameters assessed with transcutaneous ultrasound - results from the SAPALDIA cohort study

Date Issued
2013-01-01
Author(s)
Caviezel, Seraina
Dratva, Julia  
Schaffner, Emmanuel  
Teynor, Alexandra
Baumstark, Manfred W
Schindler, Christian  
de Groot, Eric
Burdet, Luc
Rothe, Thomas
Pons, Marco
Gaspoz, Jean-Michel
Rochat, Thierry
Künzli, Nino  
Probst-Hensch, Nicole  
Schmidt-Trucksäss, Arno  
DOI
10.1016/j.atherosclerosis.2013.10.010
Abstract
Objective: Carotid intima media thickness (CIMT) and local stiffness are vascular biomarkers of atherosclerotic burden. We investigated the variability and reproducibility of clinically relevant structural (CIMT, lumen diameter) and functional parameters (strain, distensibility, compliance, beta-stiffness index, Peterson's elastic modulus and Young's elastic modulus) measured in B-mode ultrasound sequences of the common carotid artery in the second follow up of the Swiss Cohort Study on Air Pollution and Lung and Heart Diseases In Adults (SAPALDIA3).Methods: Ultrasound sequential images were examined twice over a 1 cm segment across at least one heart cycle in 165 SAPALDIA3 participants. To assess variability and reproducibility of structural and functional parameters, individual coefficients of variation (CV), intraclass correlation (ICC), Bland-Altman plots and mixed effect regressions were used.Results: ICCs of repeated examinations ranged between 0.67 and 0.77 for blood pressure indices, between 0.87 and 0.97 for structural properties and between 0.75 and 0.79 for functional parameters. CV was lowest in structural parameters (1.6-4.6%), followed by blood pressure (5.1-7.9%) and functional indices (11.0-13.1%). Variations in all parameters were predominantly explained by subjects (>74% in functional, >82% in structural properties). Bland-Altman plots for functional indices showed mean and standard deviation of the respective mean value of 4.2(19.6)% for strain, 1.9(24.4)% for distensibility, 2.4(22.2)% for compliance, 3.0(24.4)% for beta-stiffness index, 0.9(25.7)% for Peterson's elastic modulus and 1.2(27.9)% for Young's elastic modulus.Conclusion: The results show that SAPALDIA3 measurements of transcutaneous ultrasound examinations have an excellent reproducibility of structural parameters and a good reproducibility of functional indices. (C) 2013 Elsevier Ireland Ltd. All rights reserved.
University of Basel

edoc
Open Access Repository University of Basel

  • About edoc
  • About Open Access at the University of Basel
  • edoc Policy

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Privacy policy
  • End User Agreement