  4. A 0/1h-algorithm using cardiac myosin-binding protein C for early diagnosis of myocardial infarction
 
  • Details

A 0/1h-algorithm using cardiac myosin-binding protein C for early diagnosis of myocardial infarction

Date Issued
2022-01-01
Author(s)
Kaier, Thomas E.
Twerenbold, Raphael  
Lopez-Ayala, Pedro  
Nestelberger, Thomas  
Boeddinghaus, Jasper  
Alaour, Bashir
Huber, Iris-Martina
Zhi, Yuan
Koechlin, Luca  
Wussler, Desiree  
Wildi, Karin  
Shrestha, Samyut
Strebel, Ivo  
Miro, Oscar
Martín-Sánchez, Javier F.
Christ, Michael
Kawecki, Damien
Keller, Dagmar I.
Rubini Gimenez, Maria
Marber, Michael
Mueller, Christian  
Apace Investigators,  
DOI
10.1093/ehjacc/zuac007
Abstract
Cardiac myosin-binding protein C (cMyC) demonstrated high diagnostic accuracy for the early detection of non-ST-elevation myocardial infarction (NSTEMI). Its dynamic release kinetics may enable a 0/1h-decision algorithm that is even more effective than the ESC hs-cTnT/I 0/1 h rule-in/rule-out algorithm.; In a prospective international diagnostic study enrolling patients presenting with suspected NSTEMI to the emergency department, cMyC was measured at presentation and after 1 h in a blinded fashion. Modelled on the ESC hs-cTnT/I 0/1h-algorithms, we derived a 0/1h-cMyC-algorithm. Final diagnosis of NSTEMI was centrally adjudicated according to the 4th Universal Definition of Myocardial Infarction. Among 1495 patients, the prevalence of NSTEMI was 17%. The optimal derived 0/1h-algorithm ruled-out NSTEMI with cMyC 0 h concentration below 10 ng/L (irrespective of chest pain onset) or 0 h cMyC concentrations below 18 ng/L and 0/1 h increase <4 ng/L. Rule-in occurred with 0 h cMyC concentrations of at least 140 ng/L or 0/1 h increase ≥15 ng/L. In the validation cohort (n = 663), the 0/1h-cMyC-algorithm classified 347 patients (52.3%) as 'rule-out', 122 (18.4%) as 'rule-in', and 194 (29.3%) as 'observe'. Negative predictive value for NSTEMI was 99.6% [95% confidence interval (CI) 98.9-100%]; positive predictive value 71.1% (95% CI 63.1-79%). Direct comparison with the ESC hs-cTnT/I 0/1h-algorithms demonstrated comparable safety and even higher triage efficacy using the 0h-sample alone (48.1% vs. 21.2% for ESC hs-cTnT-0/1 h and 29.9% for ESC hs-cTnI-0/1 h; P < 0.001).; The cMyC 0/1h-algorithm provided excellent safety and identified a greater proportion of patients suitable for direct rule-out or rule-in based on a single measurement than the ESC 0/1h-algorithm using hs-cTnT/I.; ClinicalTrials.gov number, NCT00470587.
File(s)
Loading...
Thumbnail Image
Name

20230412093525_64365f3db909e.pdf

Size

1.54 MB

Format

Adobe PDF

Checksum

(MD5):e0b897870ca3d9247edee6dc72bce7a8

University of Basel

edoc
Open Access Repository University of Basel

  • About edoc
  • About Open Access at the University of Basel
  • edoc Policy

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Privacy policy
  • End User Agreement