edoc

Atri-U: assisted image analysis in routine cardiovascular magnetic resonance volumetry of the left atrium

Anastasopoulos, Constantin and Yang, Shan and Pradella, Maurice and Akinci D'Antonoli, Tugba and Knecht, Sven and Cyriac, Joshy and Reisert, Marco and Kellner, Elias and Achermann, Rita and Haaf, Philip and Stieltjes, Bram and Sauter, Alexander W. and Bremerich, Jens and Sommer, Gregor and Abdulkadir, Ahmed. (2021) Atri-U: assisted image analysis in routine cardiovascular magnetic resonance volumetry of the left atrium. Journal of Cardiovascular Magnetic Resonance (JCMR)e Society for Cardiovascular Magnetic Resonance, 23. p. 133.

[img] PDF - Published Version
Available under License CC BY (Attribution).

1802Kb

Official URL: https://edoc.unibas.ch/87801/

Downloads: Statistics Overview

Abstract

Artificial intelligence can assist in cardiac image interpretation. Here, we achieved a substantial reduction in time required to read a cardiovascular magnetic resonance (CMR) study to estimate left atrial volume without compromising accuracy or reliability. Rather than deploying a fully automatic black-box, we propose to incorporate the automated LA volumetry into a human-centric interactive image-analysis process.; Atri-U, an automated data analysis pipeline for long-axis cardiac cine images, computes the atrial volume by: (i) detecting the end-systolic frame, (ii) outlining the endocardial borders of the LA, (iii) localizing the mitral annular hinge points and constructing the longitudinal atrial diameters, equivalent to the usual workup done by clinicians. In every step human interaction is possible, such that the results provided by the algorithm can be accepted, corrected, or re-done from scratch. Atri-U was trained and evaluated retrospectively on a sample of 300 patients and then applied to a consecutive clinical sample of 150 patients with various heart conditions. The agreement of the indexed LA volume between Atri-U and two experts was similar to the inter-rater agreement between clinicians (average overestimation of 0.8 mL/m; 2; with upper and lower limits of agreement of - 7.5 and 5.8 mL/m; 2; , respectively). An expert cardiologist blinded to the origin of the annotations rated the outputs produced by Atri-U as acceptable in 97% of cases for step (i), 94% for step (ii) and 95% for step (iii), which was slightly lower than the acceptance rate of the outputs produced by a human expert radiologist in the same cases (92%, 100% and 100%, respectively). The assistance of Atri-U lead to an expected reduction in reading time of 66%-from 105 to 34 s, in our in-house clinical setting.; Our proposal enables automated calculation of the maximum LA volume approaching human accuracy and precision. The optional user interaction is possible at each processing step. As such, the assisted process sped up the routine CMR workflow by providing accurate, precise, and validated measurement results.
Faculties and Departments:03 Faculty of Medicine > Bereich Querschnittsfächer (Klinik) > Radiologie USB
03 Faculty of Medicine > Departement Klinische Forschung > Bereich Querschnittsfächer (Klinik) > Radiologie USB
UniBasel Contributors:Anastasopoulos, Constantinos
Item Type:Article, refereed
Article Subtype:Research Article
Publisher:BMC
ISSN:1097-6647
e-ISSN:1532-429X
Note:Publication type according to Uni Basel Research Database: Journal article
Language:English
Identification Number:
edoc DOI:
Last Modified:17 May 2022 09:10
Deposited On:17 May 2022 09:10

Repository Staff Only: item control page