Accuracy of 24-hour ambulatory blood pressure monitoring by a novel cuffless device in clinical practice

Krisai, Philipp and Vischer, Annina Salome and Kilian, Leo and Meienberg, Andrea and Mayr, Michael and Burkard, Thilo. (2019) Accuracy of 24-hour ambulatory blood pressure monitoring by a novel cuffless device in clinical practice. Heart (British Cardiac Society), 105 (5). pp. 399-405.

Full text not available from this repository.

Official URL: https://edoc.unibas.ch/77028/

Downloads: Statistics Overview

Abstract

Recently, a cuffless blood pressure (BP) measurement device using pulse transit time (PTT) for beat-to-beat calculation of BP values has been validated over a short time period. However, it remains unknown how values obtained with this device compare with standard ambulatory measurements over a 24-hour period. We hypothesised that BP values measured by a cuffless PTT device (TestBP) are comparable with measurements by a standard upper arm cuff-based BP device (RefBP) in clinical practice over 24 hours.; Between May and December 2017, 71 individuals were prospectively included. Cuffless using the Somnotouch-NIBP (Somnomedics GmbH, Randersacker, Germany) and cuff-based standard 24-hour BP measurements were performed simultaneously on the left and right arm, respectively. The first RefBP measurement was used as calibration measurement for the TestBP.; Mean (±SD) age was 49.3 (15.1) years, and 51% were male. Mean 24-hour BP for TestBP and RefBP were 140.8 (20.0) versus 134.0 (17.3) mm Hg for systolic (p<0.0001) and 85.8 (14.1)versus79.3 (11.7) mm Hg for diastolic (p<0.0001) measurements, respectively. Mean absolute systolic and diastolic disagreements between TestBP and RefBP were 10.2 (7.2) and 8.2 (5.5) mm Hg, respectively. The number (percentage) of absolute differences between the mean 24-hour BP values of the TestBP and RefBP within 5, 10 and 15 mm Hg were 23 (32.4), 43 (60.6) and 54 (74.6) for systolic and 24 (33.8), 51 (71.8) and 65 (91.6) for diastolic measurements, respectively.; In clinical practice over 24 hours, there was a significant difference between the TestBP and RefBP with higher systolic and diastolic BP measured with the cuffless PTT device. Reasons for this difference need to be investigated.; NCT03054688; Results.
Faculties and Departments:03 Faculty of Medicine > Bereich Medizinische Fächer (Klinik) > Kardiologie > Klinische Outcomeforschung Kardiologie (Müller)
03 Faculty of Medicine > Departement Klinische Forschung > Bereich Medizinische Fächer (Klinik) > Kardiologie > Klinische Outcomeforschung Kardiologie (Müller)
UniBasel Contributors:Krisai, Philipp and Burkard, Thilo
Item Type:Article, refereed
Article Subtype:Research Article
ISSN:1468-201X
Note:Publication type according to Uni Basel Research Database: Journal article
Identification Number:
Last Modified:18 Aug 2020 16:58
Deposited On:18 Aug 2020 16:58

Repository Staff Only: item control page