edoc

Diagnostic accuracy of free and total metanephrines in plasma and fractionated metanephrines in urine of patients with pheochromocytoma

Grouzmann, E. and Drouard-Troalen, L. and Baudin, E. and Plouin, P. F. and Muller, B. and Grand, D. and Buclin, T.. (2010) Diagnostic accuracy of free and total metanephrines in plasma and fractionated metanephrines in urine of patients with pheochromocytoma. European Journal of Endocrinology, 162 (5). pp. 951-960.

Full text not available from this repository.

Official URL: http://edoc.unibas.ch/56789/

Downloads: Statistics Overview

Abstract

BACKGROUND: Plasma free and urinary metanephrines are recognized biomarkers for the assessment of pheochromocytoma. Plasma total metanephrines with a long half-life may represent another useful biomarker. OBJECTIVE: The aim of this study is to evaluate the diagnostic performances of plasma total metanephrines alone or combined with free metanephrines and fractionated 24-h urinary metanephrines. METHODS: A retrospective, case-control diagnostic test study was conducted between 1999 and 2007 in two university hospitals in Switzerland and two institutions in France. The patients included 46 cases with histologically proven pheochromocytoma, and 181 controls suspected of tumor with negative investigations and 3-year follow-up. None had renal dysfunction. Sensitivity and specificity were compared after expressing each measurement result as a ratio over its upper reference limit, adding the ratios of normetanephrine and metanephrine, and defining cut-off values of 1 or 2 for this sum. RESULTS: Applying a cut-off value of 1, plasma free and total metanephrines and urinary fractionated metanephrines had similar sensitivities of 96% (95% confidence interval, 86-99%), 95% (85-99%), and 95% (84-99%) along with similar specificities of 89% (83-94%), 91% (84-95%), and 86% (80-91%). A cut-off of 2 for the sum of ratios over reference limit improves the specificity, and it can be used for a confirmation test based on another biomarker taken among the three biomarkers. CONCLUSION: All three metanephrine-based tests perform equivalently for diagnosing pheochromocytoma in the absence of renal insufficiency, and can be conveniently associated two by two for confirming/excluding tumor.
Faculties and Departments:03 Faculty of Medicine > Bereich Medizinische Fächer (Klinik) > Allgemeine innere Medizin AG > Argovia Professur für Medizin (Müller)
03 Faculty of Medicine > Departement Klinische Forschung > Bereich Medizinische Fächer (Klinik) > Allgemeine innere Medizin AG > Argovia Professur für Medizin (Müller)
UniBasel Contributors:Müller, Beat
Item Type:Article, refereed
Article Subtype:Research Article
Publisher:Bio Scienctifica
ISSN:0804-4643
e-ISSN:1479-683X
Note:Publication type according to Uni Basel Research Database: Journal article
Identification Number:
Last Modified:29 Nov 2017 10:38
Deposited On:29 Nov 2017 10:38

Repository Staff Only: item control page