Diagnostic value of different adherence measures using electronic monitoring and virologic failure as reference standards

Deschamps, A. E. and De Geest, S. and Vandamme, A. M. and Bobbaers, H. and Peetermans, W. E. and Van Wijngaerden, E.. (2008) Diagnostic value of different adherence measures using electronic monitoring and virologic failure as reference standards. AIDS patient care and STDs, Vol. 22. pp. 735-743.

Full text not available from this repository.

Official URL: http://edoc.unibas.ch/dok/A6006339

Downloads: Statistics Overview

Abstract

Nonadherence to antiretroviral therapy is a substantial problem in HIV and jeopardizes the success of treatment. Accurate measurement of nonadherence is therefore imperative for good clinical management but no gold standard has been agreed on yet. In a single-center prospective study nonadherence was assessed by electronic monitoring: percentage of doses missed and drug holidays and by three self reports: (1) a visual analogue scale (VAS): percentage of overall doses taken; (2) the Swiss HIV Cohort Study Adherence Questionnaire (SHCS-AQ): percentage of overall doses missed and drug holidays and (3) the European HIV Treatment Questionnaire (EHTQ): percentage of doses missed and drug holidays for each antiretroviral drug separately. Virologic failure prospectively assessed during 1 year, and electronic monitoring were used as reference standards. Using virologic failure as reference standard, the best results were for (1) the SHCS-AQ after electronic monitoring (sensitivity, 87.5%; specificity, 78.6%); (2) electronic monitoring (sensitivity, 75%; specificity, 85.6%), and (3) the VAS combined with the SHCS-AQ before electronic monitoring (sensitivity, 87.5%; specificity, 58.6%). The sensitivity of the complex EHTQ was less than 50%. Asking simple questions about doses taken or missed is more sensitive than complex questioning about each drug separately. Combining the VAS with the SHCS-AQ seems a feasible nonadherence measure for daily clinical practice. Self-reports perform better after electronic monitoring: their diagnostic value could be lower when given independently.
Faculties and Departments:03 Faculty of Medicine > Departement Public Health > Institut für Pflegewissenschaft
UniBasel Contributors:De Geest, Sabina M.
Item Type:Article, refereed
Article Subtype:Research Article
Publisher:Mary Ann Liebert
ISSN:1087-2914
Note:Publication type according to Uni Basel Research Database: Journal article
Related URLs:
Identification Number:
Last Modified:08 Nov 2012 16:22