edoc

Items where Division is "05 Faculty of Science > Departement Chemie > Chemie > Analytische Chemie (Hauser)"

Up a level
Export as [feed] Atom [feed] RSS 1.0 [feed] RSS 2.0
Group by: Date | Item Type | Creators | Refereed
Number of items at this level: 141.

Article

Barreto, Diandra Nunes and Martins, Gabriel and Hauser, Peter C. and Mizaikoff, Boris and da Silveira Petruci, Joao Flavio. (2022) Reagent-less and sub-minute quantification of sulfite in food samples using substrate-integrated hollow waveguide gas sensors coupled to deep-UV LED. Analytica Chimica Acta, 1236. p. 340596.

Boillat, Marc-Aurèle and Hauser, Peter C.. (2022) CO2-measuring dongle. HardwareX, 12. e00338.

Chantipmanee, Nattapong and Boillat, Marc-Aurèle and Hauser, Peter C.. (2022) High voltage pulser for ion shutters in ion mobility spectrometry based on an optocoupler. Review of Scientific Instruments, 93 (7). 074703.

Chantipmanee, Nattapong and Furter, Jasmine S. and Hauser, Peter C.. (2022) Ambient ionization source based on a dielectric barrier discharge for direct testing of pharmaceuticals using ion mobility spectrometry. Analytica Chimica Acta, 1195. p. 339432.

Chantipmanee, Nattapong and Hauser, Peter C.. (2022) Determination of tobramycin in eye drops with an open-source hardware ion mobility spectrometer. Analytical and Bioanalytical Chemistry, 414 (14). pp. 4059-4066.

Keeratirawee, Kanchalar and Furter, Jasmine S. and Hauser, Peter C.. (2022) Low-cost electronic circuitry for photoacoustic gas sensing. HardwareX, 11. e00280.

Keeratirawee, Kanchalar and Hauser, Peter C.. (2022) Determination of Binary Gas Mixtures by Measuring the Resonance Frequency in a Piezoelectric Tube. Sensors, 22 (4). p. 1691.

Chantipmanee, Nattapong and Hauser, Peter C.. (2021) Development of simple drift tube design for ion mobility spectrometry based on flexible printed circuit board material. ANALYTICA CHIMICA ACTA, 1170. ARTN 338626.

Furter, Jasmine S. and Hauser, Peter C.. (2021) Compact automated capillary electrophoresis instrument for coupling with mass spectrometry by using sheathless electrospray ionization. JOURNAL OF CHROMATOGRAPHY A, 1656. ARTN 462533.

Hutanu, Andrei and Hauser, Peter C. and Moritz, Bernd and Kiessig, Steffen and Noel, Aurelie and Stracke, Jan O. and Wild, Markus and Schwarz, Maria A.. (2021) Methionine oxidation of proteins analyzed by affinity capillary electrophoresis in presence of silver(I) and gold(III) ions. ELECTROPHORESIS, 42 (11). pp. 1209-1216.

Keeratirawee, Kanchalar and Hauser, Peter C.. (2021) Photoacoustic detection of ozone with a red laser diode. TALANTA, 223. ARTN 121890.

Keeratirawee, Kanchalar and Hauser, Peter C.. (2021) Piezoelectric tube as resonant transducer for gas-phase photoacoustics. ANALYTICA CHIMICA ACTA, 1147. pp. 165-169.

Chantipmanee, Nattapong and Hauser, Peter C.. (2020) Determination of ethylene by field asymmetric ion mobility spectrometry. International journal for ion mobility spectrometry, 23 (2). pp. 161-166.

Chantipmanee, Nattapong and Sonsa-ard, Thitaporn and Fukana, Nutnaree and Kotakanok, Kamolchanok and Mantim, Thitirat and Wilairat, Prapin and Hauser, Peter C. and Nacapricha, Duangjai. (2020) Contactless conductivity detector from printed circuit board for paper-based analytical systems. Talanta, 206. p. 120227.

Furter, Jasmine S. and Boillat, Marc-Aurele and Hauser, Peter C.. (2020) Low-cost automated capillary electrophoresis instrument assembled from commercially available parts. Electrophoresis, 41 (24). pp. 2075-2082.

Hauser, Peter C. and Kuban, Pavel. (2020) Capacitively coupled contactless conductivity detection for analytical techniques - Developments from 2018 to 2020. Journal of Chromatography A, 1632. p. 461616.

Le, Thai Binh and Hauser, Peter C. and Pham, Thi Ngoc Mai and Kieu, Thi Lan Phuong and Le, Thi Phuong Quynh and Hoang, Quoc Anh and Le, Dinh Chi and Nguyen, Thi Anh Huong and Mai, Thanh Duc. (2020) Low-cost and versatile analytical tool with purpose-made capillary electrophoresis coupled to contactless conductivity detection: Application to antibiotics quality control in Vietnam. Electrophoresis, 41 (23). pp. 1980-1990.

Lienard-Mayor, Theo and Furter, Jasmine S. and Taverna, Myriam and Pham, Hung Viet and Hauser, Peter C. and Mai, Thanh Duc. (2020) Modular instrumentation for capillary electrophoresis with laser induced fluorescence detection using plug-and-play microfluidic, electrophoretic and optic modules. Analytica Chimica Acta, 1135. pp. 47-54.

Mantim, Thitirat and Chaisiwamongkhol, Korbua and Uraisin, Kanchana and Hauser, Peter C. and Wilairat, Prapin and Nacapricha, Duangjai. (2020) Dual-Purpose Photometric-Conductivity Detector for Simultaneous and Sequential Measurements in Flow Analysis. Molecules, 25 (10). ARTN 2284.

Pham, Thi Ngoc Mai and Le, Thai Binh and Le, Duc Dung and Ha, Tran Hung and Nguyen, Ngoc Son and Pham, Tien Duc and Hauser, Peter C. and Nguyen, Thi Anh Huong and Mai, Thanh Duc . (2020) Determination of carbapenem antibiotics using a purpose-made capillary electrophoresis instrument with contactless conductivity detection. Journal of Pharmaceutical and Biomedical Analysis, 178. p. 112906.

Sonsa-ard, Thitaporn and Chantipmanee, Nattapong and Fukana, Nutnaree and Hauser, Peter C. and Wilairat, Prapin and Nacapricha, Duangjai. (2020) Contactless conductivity sensor employing moist paper as absorbent for in-situ detection of generated carbon dioxide gas. Analytica Chimica Acta, 1118. pp. 44-51.

Fuiko, Roland and Saracevic, Ernis and Koenka, Israel Joel and Hauser, Peter C. and Krampe, Joerg. (2019) Capillary electrophoresis for continuous nitrogen quantification in wastewater treatment processes. Talanta, 195. pp. 366-371.

Furter, Jasmine S. and Hauser, Peter C.. (2019) Injection system for fast capillary electrophoresis based on pressure regulation with flow restrictors. Electrophoresis, 40 (3). pp. 410-413.

Furter, Jasmine S. and Hauser, Peter C.. (2019) Interactive control of purpose built analytical instruments with Forth on microcontrollers - A tutorial. Analytica chimica acta, 1058. pp. 18-28.

Kuban, Pavel and Hauser, Peter C.. (2019) Contactless conductivity detection for analytical techniques: Developments from 2016 to 2018. Electrophoresis, 40 (1). pp. 124-139.

Mai, Thanh Duc and Hauser, Peter C. and Descroix, Stephanie and de Lassichere, Cedric Crosnier and Taverna, Myriam and Smadja, Claire. (2019) In-capillary immuno-preconcentration with circulating bio-functionalized magnetic beads for capillary electrophoresis. ANALYTICA CHIMICA ACTA, 1062. pp. 156-164.

Nguyen, Thi Anh Huong and Pham, Thi Ngoc Mai and Le, Thai Binh and Le, Dinh Chi and Tran, Thi Thanh Phuong and Nguyen, Thi Quynh Hoa and Nguyen, Thi Kim Thuong and Hauser, Peter C. and Mai, Thanh Duc. (2019) Cost-effective capillary electrophoresis with contactless conductivity detection for quality control of beta-lactam antibiotics. Journal of Chromatography A, 1605. p. 360356.

Furter, Jasmine S. and Hauser, Peter C.. (2018) A low-cost ambient desorption/ionization source for mass-spectrometry based on a dielectric barrier discharge. Analytical Methods, 10 (23). pp. 2701-2711.

Kuban, Pavel and Hauser, Peter C.. (2018) 20th anniversary of axial capacitively coupled contactless conductivity detection in capillary electrophoresis. Trends in Analytical Chemistry, 102. pp. 311-321.

See, Hong Heng and Mamat, Nor Akma and Hauser, Peter C.. (2018) Flow Injection Analysis with Direct UV Detection Following Electric Field Driven Membrane Extraction. Molecules, 23 (5). p. 1000.

Steinsberger, Thomas and Kathriner, Patrick and Meier, Philipp and Mistretta, Alexander and Hauser, Peter C. and Mueller, Beat. (2018) A portable low cost coulometric micro-titrator for the determination of alkalinity in lake and sediment porewaters. Sensors and Actuators B: Chemical, 255. pp. 3558-3563.

da Silveira Petruci, Joao Flavio and Hauser, Peter C. and Cardoso, Arnaldo Alves. (2018) Colorimetric paper-based device for gaseous hydrogen cyanide quantification based on absorbance measurements. Sensors and actuators. B, Chemical, 268. pp. 392-397.

Bui, Duy Anh and Kraiczek, Karsten G. and Hauser, Peter C.. (2017) Molecular absorption measurements with an optical fibre coupled array of ultra-violet light-emitting diodes. Analytica Chimica Acta, 986. pp. 95-100.

Koenka, Israel Joel and Hauser, Peter C.. (2017) Background conductivity independent counter flow preconcentration method for capillary electrophoresis. Electrophoresis, 38 (21). pp. 2721-2724.

Kuban, Pavel and Hauser, Peter C.. (2017) Contactless conductivity detection for analytical techniques Developments from 2014 to 2016. Electrophoresis, 38 (1). pp. 95-114.

Petruci, Joao Flavio da Silveira and Liebetanz, Michael G. and Cardoso, Arnaldo Alves and Hauser, Peter C.. (2017) Absorbance detector for high performance liquid chromatography based on a deep-UV light-emitting diode at 235 nm. Journal of Chromatography A, 1512. pp. 143-146.

Vu, Anh Phuong and Nguyen, Thi Ngan and Do, Thi Trang and Doan, Thu Ha and Ha, Tran Hung and Ta, Thi Thao and Nguyen, Hung Long and Hauser, Peter C. and Nguyen, Thi Anh Huong and Mai, Thanh Duc. (2017) Clinical screening of paraquat in plasma samples using capillary electrophoresis with contactless conductivity detection: Towards rapid diagnosis and therapeutic treatment of acute paraquat poisoning in Vietnam. Journal of Chromatography B, 1060. pp. 111-117.

Bui, Duy Anh and Hauser, Peter C.. (2016) A deep-UV light-emitting diode-based absorption detector for benzene, toluene, ethylbenzene, and the xylene compounds. Sensors and Actuators B: Chemical, 235. pp. 622-626.

Caslavska, Jitka and Koenka, Israel Joel and Hauser, Peter C. and Thormann, Wolfgang . (2016) Validation of CE modeling with a contactless conductivity array detector. Electrophoresis, 37 (5-6). pp. 699-710.

Koenka, Israel Joel and Kung, Nina and Kuban, Pavel and Chwalek, Thomas and Furrer, Gerhard and Wehrli, Bernhard and Muller, Beat and Hauser, Peter C.. (2016) Thermostatted dual-channel portable capillary electrophoresis instrument. Electrophoresis, 37 (17-18). pp. 2368-2375.

Koenka, Israel Joel and Mai, Thanh Duc and Hauser, Peter C. and Sáiz, Jorge . (2016) Simultaneous separation of cations and anions in capillary electrophoresis - recent applications. Analytical Methods, 8 (7). pp. 1452-1456.

Koenka, Israel Joel and Sáiz, Jorge and Rempel, Paul and Hauser, Peter C.. (2016) Microfluidic Breadboard Approach to Capillary Electrophoresis. Analytical Chemistry, 88 (7). pp. 3761-3767.

Mai, Thanh Duc and Le, Minh Duc and Sáiz, Jorge and Duong, Hong Anh and Koenka, Israel Joel and Pham, Hung Viet and Hauser, Peter C.. (2016) Triple-channel portable capillary electrophoresis instrument with individual background electrolytes for the concurrent separations of anionic and cationic species. Analytica Chimica Acta, 911. pp. 121-128.

Nguyen, Thi Anh Huong and Nguyen, Van Ri and Le, Duc Dung and Nguyen, Thi Thanh Binh and Cao, Van Hoang and Nguyen, Thi Kim Dung and Sáiz, Jorge and Hauser, Peter C. and Mai, Thanh Duc. (2016) Simultaneous determination of rare earth elements in ore and anti-corrosion coating samples using a portable capillary electrophoresis instrument with contactless conductivity detection. Journal of Chromatography A, 1457. pp. 151-158.

Torres, Natascha T. and Steinsberger, Thomas and Droz-Georget, Helen and Muller, Beat and Brandl, Helmut and Hauser, Peter C. and Furrer, Gerhard. (2016) A Novel Method to Quantify Bioavailable Elements and Mobile ATP on Rock Surfaces and Lichens. AIMS Geosciences, 2 (3). pp. 245-258.

Bui, D. A. and Hauser, P. C.. (2015) Analytical devices based on light-emitting diodes – a review of the state-of-the-art. Analytica chimica acta, 853. pp. 46-58.

Bui, Duy Anh and Hauser, Peter C.. (2015) Absorbance detector for capillary electrophoresis based on light-emitting diodes and photodiodes for the deep-ultraviolet range. Journal of Chromatography A, 1421. pp. 203-208.

Bui, Duy Anh and Hauser, Peter C.. (2015) Deep UV-LED Based Absorbance Detectors for Narrow-Bore HPLC and Capillary Electrophoresis. Chimia, 69 (12). p. 806.

Duong, H. A. and Le, M. D. and Nguyen, K. D. M. and Hauser, P. C. and Pham, H. V. and Mai, T. D.. (2015) In-house-made capillary electrophoresis instruments coupled with contactless conductivity detection as a simple and inexpensive solution for water analysis: a case study in Vietnam. Environmental Science: Processes & Impacts, 17 (11). pp. 1941-1951.

Koenka, Israel Joel and Sáiz, Jorge and Hauser, Peter C.. (2015) Instrumentino: An Open-Source Software for Scientific Instruments. Chimia, 69 (4). pp. 172-175.

Kuban, P. and Hauser, P. C.. (2015) Contactless conductivity detection for analytical techniques-Developments from 2012 to 2014. Electrophoresis, 36 (1). pp. 195-211.

Nguyen, H. T. A. and Pham, T. N. M. and Ta, T. T. and Nguyen, X. T. and Nguyen, T. L. and Le, T. H. H. and Koenka, I. J. and Sáiz, J. and Hauser, P. C. and Mai, T. D.. (2015) Screening determination of four amphetamine-type drugs in street-grade illegal tablets and urine samples by portable capillary electrophoresis with contactless conductivity detection. Science & justice, 55 (6). pp. 481-486.

Saiz, J. and Koenka, I. J. and Garcia-Ruiz, C. and Muller, B. and Chwalek, T. and Hauser, P. C.. (2015) Micro-injector for capillary electrophoresis. Electrophoresis, 36 (16). pp. 1941-1944.

Seitz, P. and Senesky, D. G. and Schoning, M. J. and Hauser, P. C. and Moser, R. and Herzig, H. P. and Melesse, A. M. and Broderick, P. A. and Eugster, P. T.. (2015) 4th International Symposium on Sensor Science (I3S2015): Conference Report. Sensors, 15 (9). pp. 24458-24465.

Vontobel, S. F. and Abad-Villar, E. M. and Kaufmann, C. and Zinkernagel, A. S. and Hauser, P. C. and Thiel, M. A.. (2015) Corneal Penetration of Polyhexamethylene Biguanide and Chlorhexidine Digluconate. Journal of Clinical & Experimental Ophthalmology. p. 1000430.

Koenka, I. J. and Sáiz, J. and Hauser, P. C.. (2014) Instrumentino: An open-source modular Python framework for controlling Arduino based experimental instruments. Computer physics communications, Vol. 185, H. 10. pp. 2724-2729.

Nguyen, T. A. H. and Pham, T. N. M. and Doan, T. T. and Ta, T. T. and Saiz, J. and Nguyen, T. Q. H. and Hauser, P. C. and Mai, T. D.. (2014) Simple semi-automated portable capillary electrophoresis instrument with contactless conductivity detection for the determination of beta-agonists in pharmaceutical and pig-feed samples. Journal of chromatography A, Vol. 1360. pp. 305-311.

Pham, T. T. T. and Mai, T. D. and Nguyen, T. D. and Sáiz, J. and Pham, H. V. and Hauser, P. C.. (2014) Automated dual capillary electrophoresis system with hydrodynamic injeciton for the concurrent determination of cations and anions. Analytica chimica acta, Vol. 841. pp. 77-83.

Saiz, Jorge and Koenka, Israel Joel and Thanh Duc Mai, and Hauser, Peter C. and Garcia-Ruiz, Carmen. (2014) Simultaneous separation of cations and anions in capillary electrophoresis. Trends in Analytical Chemistry, 62. pp. 162-172.

See, H. H. and Hauser, P.. (2014) Automated Electric-Field-Driven Membrane Extraction System Coupled to Liquid Chromatography-Mass Spectrometry. Analytical chemistry, Vol. 86, H. 17. pp. 8665-8670.

See, H. H. and Hauser, P. C.. (2014) Electro-driven extraction of low levels of lipophilic organic anions and cations across plasticized cellulose triacetate membranes : effect of the membrane composition. Journal of membrane science, Vol. 450. pp. 147-152.

Stojkovic, M. and Koenka, I. J. and Thormann, W. and Hauser, P. C.. (2014) Contactless conductivity detector array for capillary electrophoresis. Electrophoresis, Vol. 35, H. 4. pp. 482-486.

Sáiz, J. and Mai, T. D. and Koenka, I. J. and Martín-Alberca, C. and Hauser, P. C. and García Ruiz, C.. (2014) Concurrent determination of anions and cations in consumer fireworks with a portable dual-capillary electrophoresis system. Journal of chromatography A, Vol. 1372. pp. 245-252.

Torres, N. T. and Och, L. M. and Hauser, P. C. and Furrer, G. and Brandl, H. and Vologina, E. and Sturm, M. and Bürgmann, H. and Müller, B.. (2014) Early diagenetic processes generate iron and manganese oxide layers in the sediments of Lake Baikal, Siberia. Environmental Science : processes & impacts, Vol. 16, H. 4. pp. 879-889.

Ansari, K. and Ying, J. Y. S. and Hauser, P. C. and de Rooij, N. F. and Rodriguez, I.. (2013) A portable lab-on-a-chip instrument based on MCE with dual topbottom capacitive coupled contactless conductivity detector in replaceable cell cartridge. Electrophoresis, Vol. 34, H. 9-10. pp. 1390-1399.

Buglione, L. and See, H. H. and Hauser, P. C.. (2013) Rapid separation of fatty acids using a poly(vinyl alcohol) coated capillary in nonaqueous capillary electrophoresis with contactless conductivity detection. Electrophoresis, Vol. 34, H. 14. pp. 2072-2077.

Buglione, L. and See, H. H. and Hauser, P. C.. (2013) Study on the effects of electrolytes and solvents in the determination of quaternary ammonium ions by nonaqueous capillary electrophoresis with contactless conductivity detection. Electrophoresis, Vol. 34, H. 2. pp. 317-323.

Bui, D. A. and Bomastyk, B. and Hauser, P. C.. (2013) Absorbance detector based on a deep UV light emitting diode for narrow-column HPLC. Journal of separation science, Vol. 36, H. 19. pp. 3152-3157.

Bui, D. A. and Hauser, P. C.. (2013) Absorbance measurements with light-emitting diodes as sources: Silicon photodiodes or light-emitting diodes as detectors? Talanta, Vol. 116. pp. 1073-1078.

Kamaruzaman, S. and Hauser, P. C. and Sanagi, M. M. and Ibrahim, W. A. W. and Endud, S. and See, H. H.. (2013) A simple microextraction and preconcentration approach based on a mixed matrix membrane. Analytica chimica acta, Vol. 783. pp. 24-30.

Kuban, P. and Hauser, P. C.. (2013) Contactless conductivity detection for analytical techniques : developments from 2010 to 2012. Electrophoresis, Vol. 34, H. 1. pp. 55-69.

Mai, T. D. and Hauser, P. C.. (2013) Study on the interrelated effects of capillary diameter, background electrolyte concentration, and flow rate in pressure assisted capillary electrophoresis with contactless conductivity detection. Electrophoresis, Vol. 34, H. 12. pp. 1796-1803.

Mai, T. D. and Pham, T. T. T. and Pham, H. V. and Saiz, J. and Ruiz, C. G. and Hauser, P. C.. (2013) Portable Capillary Electrophoresis Instrument with Automated Injector and Contactless Conductivity Detection. Analytical chemistry, Vol. 85, H. 4. pp. 2333-2339.

Saiz, J. and Mai, T. D. and Hauser, P. C. and Garcia-Ruiz, C.. (2013) Determination of nitrogen mustard degradation products in water samples using a portable capillary electrophoresis instrument. Electrophoresis, Vol. 34, H. 14. pp. 2078-2084.

Saiz, J. and Mai, T. D. and Lopez, M. L. and Bartolome, C. and Hauser, P. C. and Garcia-Ruiz, C.. (2013) Rapid determination of scopolamine in evidence of recreational and predatory use. Science & justice, Vol. 53, H. 4. pp. 409-414.

Schmidt-Marzinkowski, J. and See, H. H. and Hauser, P. C.. (2013) Electric Field Driven Extraction of Inorganic Anions Across a Polymer Inclusion Membrane. Electroanalysis, Vol. 25, no. 8. pp. 1879-1886.

See, H. H. and Stratz, S. and Hauser, P. C.. (2013) Electro-driven extraction across a polymer inclusion membrane in a flow-through cell. Journal of chromatography A, Vol. 1300. pp. 79-84.

Stojkovic, M. and Mai, T. D. and Hauser, P. C.. (2013) Determination of artificial sweeteners by capillary electrophoresis with contactless conductivity detection optimized by hydrodynamic pumping. Analytica chimica acta, Vol. 787. pp. 254-259.

Stojkovic, M. and Schlensky, B. and Hauser, P. C.. (2013) Referenced Capacitively Coupled Conductivity Detector for Capillary Electrophoresis. Electroanalysis, Vol. 25, no. 12. pp. 2645-2650.

Stojkovic, M. and Uda, N. R. and Brodmann, P. and Hauser, P. C.. (2013) Determination of PCR Products by Capillary Electrophoresis with Contactless Conductivity Detection. Chimia, 67 (6). p. 428.

Torres, N. T. and Hauser, P. C. and Furrer, G. and Brandl, H. and Muller, B.. (2013) Sediment porewater extraction and analysis combining filter tube samplers and capillary electrophoresis. Environmental Science, Vol. 15, H. 4. pp. 715-720.

Mai, T. D. and Bomastyk, B. and Duong, H. A. and Pham, H. V. and Hauser, P. C.. (2012) Automated capillary electrophoresis with on-line preconcentration by solid phase extraction using a sequential injection manifold and contactless conductivity detection. Analytica Chimica Acta, Vol. 727. pp. 1-7.

Mai, T. D. and Hauser, P. C.. (2012) Contactless conductivity detection for electrophoretic microseparation techniques. The chemical record, Vol. 12, H. 1. pp. 106-113.

Mai, T. D. and Hauser, P. C.. (2012) Simultaneous separations of cations and anions by capillary electrophoresis with contactless conductivity detection employing a sequential injection analysis manifold for flexible manipulation of sample plugs. Journal of chromatography A, Vol. 1267. pp. 266-272.

Mantim, T. and Nacapricha, D. and Wilairat, P. and Hauser, P. C.. (2012) Enantiomeric separation of some common controlled stimulants by capillary electrophoresis with contactless conductivity detection. Electrophoresis, Vol. 33, H. 2. pp. 388-394.

Pham, T. T. T. and See, H. H. and Morand, R. and Krahenbuhl, S. and Hauser, P. C.. (2012) Determination of free and total valproic acid in human plasma by capillary electrophoresis with contactless conductivity detection. Journal of chromatography. B, Analytical technologies in the biomedical and life sciences, Vol. 907. pp. 74-78.

See, Hong Heng and Schmidt-Marzinkowski, Julia and Pormsila, Worapan and Morand, Réjane and Krähenbühl, Stephan and Hauser, Peter C.. (2012) Determination of creatine and phosphocreatine in muscle biopsy samples by capillary electrophoresis with contactless conductivity detection. Analytica Chimica Acta, 727. pp. 78-82.

Stojkovic, M. and Uda, N. R. and Brodmann, P. and Popovic, M. and Hauser, P. C.. (2012) Determination of PCR products by CE with contactless conductivity detection. Journal of separation science, Vol. 35, H. 24. pp. 3509-3513.

Bomastyk, B. and Petrovic, I. and Hauser, P. C.. (2011) Absorbance detector for high-performance liquid chromatography based on light-emitting diodes for the deep-ultraviolet range. Journal of chromatography A, Vol. 1218, H. 24. pp. 3750-3756.

Guijt, R. M. and Armstrong, J. P. and Candish, E. and Lefleur, V. and Percey, W. J. and Shabala, S. and Hauser, P. C. and Breadmore, M. C.. (2011) Microfluidic chips for capillary electrophoresis with integrated electrodes for capacitively coupled conductivity detection based on printed circuit board technology. Sensors and Actuators B: Chemical, 159 (1). pp. 307-313.

Kubáň, P. and Hauser, P. C.. (2011) Capacitively coupled contactless conductivity detection for microseparation techniques - recent developments. Electrophoresis, Vol. 32, H. 1. pp. 30-42.

Lau, H. F. and Quek, N. M. and Law, W. S. and Zhao, J. H. and Hauser, P. C. and Li, S. F. Y.. (2011) Optimization of separation of heavy metals by capillary electrophoresis with contactless conductivity detection. Electrophoresis, 32 (10). pp. 1190-1194.

Mai, T. D. and Hauser, P. C.. (2011) Anion separations with pressure-assisted capillary electrophoresis using a sequential injection analysis manifold and contactless conductivity detection. Electrophoresis, Vol. 32, H. 21. pp. 3000-3007.

Mai, T. D. and Hauser, P. C.. (2011) Pressure-assisted capillary electrophoresis for cation separations using a sequential injection analysis manifold and contactless conductivity detection. Talanta, Vol. 84, H. 5. pp. 1228-1233.

Pormsila, Worapan and Morand, Réjane and Krähenbühl, Stephan and Hauser, Peter C.. (2011) Capillary electrophoresis with contactless conductivity detection for the determination of carnitine and acylcarnitines in clinical samples. Journal of Chromatography B, 879 (13-14). pp. 921-926.

Pormsila, Worapan and Morand, Réjane and Krähenbühl, Stephan and Hauser, Peter C.. (2011) Quantification of plasma lactate concentrations using capillary electrophoresis with contactless conductivity detection. Electrophoresis, 32 (8). pp. 884-889.

See, H. H. and Hauser, P. C.. (2011) Electric Field-Driven Extraction of Lipophilic Anions across a Carrier-Mediated Polyme Inclusion Membrane. Analytical chemistry, Vol. 83, H. 19. pp. 7507-7513.

Hauser, P. C.. (2010) Analytical Sciences. Chimia, 64 (12). pp. 871-873.

Mahabadi, K. A. and Rodriguez, I. and Lim, C. Y. and Maurya, D. K. and Hauser, P. C. and de Rooij, N. F.. (2010) Capacitively coupled contactless conductivity detection with dual top-bottom cell configuration for microchip electrophoresis. Electrophoresis, Vol. 31, H. 6. pp. 1063-1070.

Pormsila, W. and Gong, X. Y. and Hauser, P. C.. (2010) Determination of the enantiomers of alpha-hydroxy- and alpha-amino acids in capillary electrophoresis with contactless conductivity detection. Electrophoresis, Vol. 31. pp. 2044-2048.

Pormsila, W. and Krähenbühl, S. and Hauser, P. C.. (2010) Determination of carnitine in food and food supplements by capillary electrophoresis with contactless conductivity detection. Electrophoresis, Vol. 31. pp. 2186-2191.

Ryvolova, M. and Preisler, J. and Foret, F. and Hauser, P. C. and Krasensky, P. and Paull, B. and Macka, M.. (2010) Combined Contactless Conductometric, Photometric, and Fluorimetric Single Point Detector for Capillary Separation Methods. Analytical chemistry, Vol. 82, H. 1. pp. 129-135.

Schuchert-Shi, A. and Hauser, P. C.. (2010) Following the Lipase Catalyzed Enantioselective Hydrolysis of Amino Acid Esters with Capillary Electrophoresis Using Contactless Conductivity Detection. Chirality, Vol. 22, H. 3. pp. 331-335.

See, H. H. and Hauser, P. C. and Ibrahim, W. A. W. and Sanagi, M. M.. (2010) Rapid and direct determination of glyphosate, glufosinate, and aminophosphonic acid by online preconcentration CE with contactless conductivity detection. Electrophoresis, Vol. 31, H. 3. pp. 575-582.

See, H. H. and Hauser, P. C. and Sanagi, M. M. and Ibrahim, W. A. W.. (2010) Dynamic supported liquid membrane tip extraction of glyphosate and aminomethylphosphonic acid followed by capillary electrophoresis with contactless conductivity detection. Journal of chromatography A, Vol. 1217, H. 37. pp. 5832-5838.

Thanh, D. M. and Schmid, S. and Müller, B. and Hauser, P. C.. (2010) Capillary electrophoresis with contactless conductivity detection coupled to a sequential injection analysis manifold for extended automated monitoring applications. Analytica Chimica Acta, Vol. 665, H. 1. pp. 1-6.

Krčmová, L. and Stjernlof, A. and Mehlen, S. and Hauser, P. C. and Abele, S. and Paull, B. and Macka, M.. (2009) Deep-UV-LEDs in photometric detection: a 255 nm LED on-capillary detector in capillary electrophoresis. The analyst, 134. pp. 2394-2396.

Kubáň, P. and Hauser, P. C.. (2009) Fundamentals of electrochemical detection techniques for CE and MCE. Electrophoresis, Vol. 30, H. 19. pp. 3305-3314.

Kubáň, P. and Hauser, P. C.. (2009) Ten years of axial capacitively coupled contactless conductivity detection for CZE : a review. Electrophoresis, Vol. 30, H. 1. pp. 176-188.

Mai, T. D. and Pham, H. V. and Hauser, P. C.. (2009) Capillary electrochromatography with contactless conductivity detection for the determination of some inorganic and organic cations using monolithic octadecylsilica columns. Analytica Chimica Acta, Vol. 653, pp. 228-233.

Pormsila, W. and Krahenbuhl, S. and Hauser, P. C.. (2009) Capillary electrophoresis with contactless conductivity detection for uric acid determination in biological fluids. Analytica Chimica Acta, Vol. 636, pp. 224-228.

Schuchert-Shi, A. and Hauser, P. C.. (2009) Peptic and tryptic digestion of peptides and proteins monitored by capillary electrophoresis with contactless conductivity detection. Analytical Biochemistry, Vol. 387, H. 2. pp. 202-207.

Schuchert-Shi, A. and Hauser, P. C.. (2009) Study of acetylcholinesterase inhibitors using CE with contactless conductivity detection. Electrophoresis, Vol. 30, H. 19. pp. 3442-3448.

Xu, Li and Hauser, Peter C. and Lee, Hian Kee. (2009) Determination of nerve agent degradation products by capillary electrophoresis using field-amplified sample stacking injection with the electroosmotic flow pump and contactless conductivity detection. Journal of Chromatography A, 1216 (31). pp. 5911-5916.

Gillespie, Eoin and Connolly, Damian and Macka, Mirek and Hauser, Peter and Paull, Brett. (2008) Development of a contactless conductivity detector cell for 1.6 mm OD (1/16th inch) HPLC tubing and micro-bore columns with on-column detection. Analyst, 133 (8). pp. 1104-1110.

Gong, Xiao Yang and Dobrunz, Dorninik and Kumin, Michael and Wiesner, Markus and Revell, Jefferson D. and Wennemers, Helma and Hauser, Peter C.. (2008) Separating stereoisomers of di-, tri-, and tetrapeptides using capillary electrophoresis with contactless conductivity detection. Journal of Separation Science, 31 (3). pp. 565-573.

Gong, Xiao Yang and Kuban, Pavel and Scholer, Andre and Hauser, Peter C.. (2008) Determination of gamma-hydroxybutyric acid in clinical samples using capillary electrophoresis with contactless conductivity detection. Journal of Chromatography A, 1213 (1). pp. 100-104.

Kuban, Pavel and Hauser, Peter C.. (2008) A review of the recent achievements in capacitively coupled contactless conductivity detection. Analytica Chimica Acta, 607. pp. 15-29.

Kuban, Pavel and Hauser, Peter C.. (2008) Evaluation of microchip capillary electrophoresis with external contactless conductivity detection for the determination of major inorganic ions and lithium in serum and urine samples. Lab on a Chip, 8 (11). pp. 1829-1836.

Kuban, Pavel and Kuban, Petr and Kuban, Vlastimil and Hauser, Peter C. and Bocek, Petr. (2008) Capillary electrochromatography of inorganic cations in open tubular columns with a controllable capacity multilayered stationary phase architecture. Journal of chromatography A, 1190 (1-2). pp. 377-382.

Quek, Ngee Mien and Law, Wai Siang and Lau, Hiu Fung and Zhao, Jian Hong and Hauser, Peter C. and Li, Sam Fong Yau. (2008) Determination of pharmaceuticals classified as emerging pollutants using capillary electrophoresis with capacitively coupled contactless conductivity detection. Electrophoresis, 29 (17). pp. 3701-3709.

Schmid, Stefan and Macka, Mirek and Hauser, Peter C.. (2008) Deep-UV Detector for HPLC with Light-Emitting Diode. Chimia, 62 (10). p. 860.

Schmid, Stefan and Macka, Mirek and Hauser, Peter C.. (2008) UV-absorbance detector for HPLC based on a light-emitting diode. Analyst, 133 (4). pp. 465-469.

Schuchert-Shi, Aiping and Hauser, Peter C.. (2008) Monitoring the enzymatic conversion of urea to ammonium by conventional or microchip capillary electrophoresis with contactless conductivity detection. Analytical Biochemistry, 376 (2). pp. 262-267.

Xu, Li and Gong, Xiao Yang and Lee, Hian Kee and Hauser, Peter C.. (2008) Ion-pair liquid-liquid-liquid microextraction of nerve agent degradation products followed by capillary electrophoresis with contactless conductivity detection. Journal of Chromatography A, 1205 (1-2). pp. 158-162.

Xu, Li and Hauser, Peter C. and Lee, Hian Kee. (2008) Electro membrane isolation of nerve agent degradation products across a supported liquid membrane followed by capillary electrophoresis with contactless conductivity detection. Journal of Chromatography A, 1214 (1-2). pp. 17-22.

Book Section

Hauser, Peter C.. (2017) Analytical Methods for the Determination of Lead in the Environment. In: Lead: Its Effects on Environment and Health, 17. Berlin, pp. 49-59.

Hauser, Peter C.. (2016) Determination of Alkali Ions in Biological and Environmental Samples. In: Alkali Metal Ions: Their Role for Life. Berlin, pp. 11-25.

Thesis

Chantipmanee, Nattapong. STUDY OF DETECTION OF INORGANIC IONS BY ELECTROSPRAY MASS SPECTROMETRY AND DEVELOPMENT OF ION MOBILITY SPECTROMETRY AND ITS APPLICATIONS. 2022, Doctoral Thesis, University of Basel, Faculty of Science.

Furter, Jasmine. Microfluidic based injection systems for capillary electrophoresis coupled to contactless conductivity, fluorescence and mass spectrometric detection. 2022, Doctoral Thesis, University of Basel, Faculty of Science.

Rehm, Sophia. Measurement of antibiotics using LC-MS/MS. 2020, Doctoral Thesis, University of Basel, Faculty of Science.

Ferenc, Alena. Analysis of protein modifications in biopharmaca by capillary electrophoresis and high-performance liquid chromatography : monitoring deamidation, charge variant distribution, and PEGylation. 2017, Doctoral Thesis, University of Basel, Faculty of Science.

Koenka, Israel Joel. Advances in capillary electrophoresis using microfluidics. 2017, Doctoral Thesis, University of Basel, Faculty of Science.

Bui, Duy Anh. Light-emitting diodes and photodiodes in the deep ultra-violet range for absorption photometry in liquid chromatography, capillary electrophoresis and gas sensing. 2016, Doctoral Thesis, University of Basel, Faculty of Science.

Torres, Natascha. Applications of a portable capillary electrophoresis instrument in environmental science. 2015, Doctoral Thesis, University of Basel, Faculty of Science.

Stojkovic, Marko. Further development and applications of capillary electrophoresis with capacitively coupled contactless conductivity detection and sequential injection analysis in analytical chemistry. 2013, Doctoral Thesis, University of Basel, Faculty of Science.

Mai, Thanh Duc. Capacitively coupled contactless conductivity detection and sequential injection analysis in capillary electrophoresis and capillary electro-chromatography. 2011, Doctoral Thesis, University of Basel, Faculty of Science.

Pormsila, Worapan. Development of capillary electrophoresis with capacitively coupled contactless conductivity detection for clinical analysis and related applications. 2010, Doctoral Thesis, University of Basel, Faculty of Science.

Schuchert-Shi, Aiping. Monitoring of enzymatic reactions using capillary electrophoresis with conductivity detection. 2009, Doctoral Thesis, University of Basel, Faculty of Science.

Gong, Xiao-Yang. Applications of capillary electrophoresis with contactless conductivity detection. 2008, Doctoral Thesis, University of Basel, Faculty of Science.

Sturm, Stefan. A general unknown screening for drugs and toxic compounds in human serum. 2005, Doctoral Thesis, University of Basel, Faculty of Science.

This list was generated on Thu Mar 28 03:57:00 2024 CET.